iT600 VS20W - Installer - User Manual 011_Layout 1 07.07.2014 10:38 Stron
Installation - Device Parameters continued
DX
D08
D09
D10
D11
D12
D13
D14
D15
D16
FUNCTION
SYSTEM SETTING
Frost Set point
5-17 Deg C
Temperature
Hour Format
0
1
N/A
N/A
Daylight Saving
0
Time (DST)
1
Heating Set point
5-35 Deg C
Limit
Cooling Set point
5-40 Deg C
Limit
Floor sensor High
Limit Temperature
6-45 Deg C
Floor sensor Low
Limit Temperature
6-45 Deg C
Floor sensor Limit
for cooling
6-45 Deg C
DEFINITION
Required Temperature for frost
protection and holiday mode
12
24
N/A
OFF
ON
Maximum temp that can
be set for heating
Maximum temp that can
be set for Cooling
Output relay will be switched off
when temp is reached for
floor protection
Output relay will be switched on
when temp is reached for
floor protection
Output relay will be switched off
when temp is reached for
floor protection
VS20WRF and VS20BRF Installer Manual
DEFAULT
5 Deg
1
N/A
1
35 Deg C
5 Deg C
27 Deg C
10 Deg C
6 Deg C
59