Nikon Eclipse Ni-E Instruction Manual page 69

Upright motorized microscope
Hide thumbs Also See for Eclipse Ni-E:
Table of Contents

Advertisement

Tube
Arm
Nosepiece
Substage
Stage
Condenser holder
Condenser
Control Box A
Power cord
Chapter 4
Binocular tube (binocular section 100%)
Trinocular tube F
(Binocular : adapter = 100:0, 0:100)
Trinocular tube T
(Binocular : adapter = 100:0, 20:80, 0:100)
Ergonomic tube
(Binocular section 100%)
(with DSC port mounted, binocular : DSC port = 50:50)
Quadrocular tilting tube, motorized quadrocular tilting tube
(Binocular : adapter = 100:0, 0:100)
(with DSC port mounted, binocular : adapter : DSC port = 0:0:100)
Standard arm
Contact arm: required for motorized operation
Universal quintuple, BD quintuple, sextuple, sextuple with analyzer slot, DIC sextuple,
intelligent DIC sextuple, intelligent septuple, motorized DIC sextuple, and motorized
septuple
For both rotatable ceramic coated stage and motorized XY stage
Rotatable ceramic coated stage centering screws
Attached to the elevating section of the main body
• Right/left handle rotatable ceramic coated stage
Travel range: X: ±78 mm, Y: ±54 mm
Rotation angle: The stage can be rotated clockwise by 195° and counterclockwise by 7°
from the reference position (rotation angle 0°).
The stage is equipped with a specimen holder.
• Motorized XY stage
Travel range: X: ±34 mm, Y: ±27 mm
For manual condenser. Equipped with a condenser focus knob and condenser centering
screws.
Attached to a substage
Motorized/manual universal condenser:
Attach optical modules for differential interference contrast, phase contrast, or dark-field
microscopy to a turret.
Motorized universal condenser can be attached to substage by itself. Equipped with
condenser focus knob, condenser centering screws
DIC condenser (oil):
Differential interference contrast optical module OIL (slider) attached
Other condensers:
Abbe condenser, achromat condenser, dark field condenser (dry and oil), aplanatic
condenser, X LWD condenser, 2-100X slide achro condenser, 1-100X achromat swing-out
condenser
Input ratings: 100-240VAC, 50/60Hz, 5.0A
• When used in 100-120 V regions outside Japan
UL listed detachable power cord set, 3 conductor grounding
(3 conductor grounding Type SVT, No.18 AWG, 3 m long maximum, rated at 125 VAC
minimum)
• When used in 220-240 V regions
Detachable power cord set approved according to EU/EN standard, 3 conductor
grounding
(3 conductor grounding Type H05VV-F, 3 m long maximum, rated at 250 VAC minimum)
• When used inside Japan
PSE approved detachable power cord set, 3 conductor grounding
(3 conductor grounding Type VCTF 3 x 0.75 mm
minimum)
Specifications
2
, 3 m long maximum, rated at 125 VAC