Register
No. for
Name
No.
Trans-
mission
101
Speed search deceleration
0165
#3
time
102
Speed search operation
0166
#3
level
103
0167 Torque compensation gain
Torque compensation
104
0168
time constant
105
0169 Torque compensation iron
loss
106
016A
Motor rated slip
107
016B Line to neutral (per phase) 0.000 to 65.50Ω
108
016C Motor leakage inductance 0.00 to 655.0mH
Torque compensation
109 016D
voltage limitter
110
016E Motor no-load current
111
016F Slip compensation gain
Slip compensation time
112
0170
constant
Slip correction during
113
0171
regenerative operation
Stall prevention automatic
115
0173
decrease selection
#2
Accel / decel time during
116
0174
stall prevention
#2
117
Undertorque detection
0175
#3
function selection 1
118
0176
Undertorque detection level
#3
119
0177
Undertorque detection time
#3
Setting
Setting
Range
Unit
0.1 to 10.0s
0.1s
0 to 200%
1%
0.0 to 2.5
0.1
0.1s
0.0 to 25.5s
0.01W (less than
0.0 to 6550
1000W) /
1W (1000W or
more)
0.0 to 20.0Hz
0.1Hz
0.001Ω (less than
10Ω) /
0.01Ω (10Ω or
more)
0.01mH (less
than 100mH) /
0.1mH (100mH
or more)
0 to 250%
1%
0 to 99%
1%
0.0 to 2.5
0.1
0.0 to 25.5s
0.1s
0, 1
1
0, 1
1
0, 1
1
0 to 4
1
0 to 200%
1%
0.1 to 10.0s
0.1s
Initial
User
Ref.
Setting
Setting
Page
2.0s
62
150%
62
1.0
44
0.3s
44
44
(note 3)
(note 3)
46
(note 3)
46
(note 3)
46
150%
(Note 3)
45
0.0
86
2.0s
86
0
0
84
85
0
0
126
10%
126
0.1s
126
165