Connection Example of Braking Resistor
(R)
3-PHASE
POWER
(S)
SUPPLY
(T)
THRX OFF
BRAKING RESISTOR UNIT
OVERLOAD RELAY TRIP CONTACT
MC
FAULT CONTACT
* Disable stall prevention during deceleration by setting n092 to 1 when
using a Braking Resistor Unit. The motor may not stop within the
deceleration time if this setting is not changed.
152
Use sequencer to break
power supply side on
overload
relay
contact
MCCB
MC
ON
MC
MC
SA
THRX
SA
TRX
SA
MA MC
TRX
OVERLOAD RELAY
TRIP CONTACT
trip
B1
B2
L1(R)
N/L2(S)
L3(T)
W/T3
BRAKING
RESISTOR
MOTOR
U/T1
V/T2
IM