YASKAWA VS-606V7 Series Instruction Manual page 147

Compact general-purpose inverter (voltage vector control)
Hide thumbs Also See for VS-606V7 Series:
Table of Contents

Advertisement

Voltage Class
phase
Model
CIMR-V7
C????
*
Single-
phase
Status Indicator
LED
Digital Operator
(JVOP-140)
Terminals
Wiring Distance
between Inverter
and Motor
Enclosure
Cooling Method
Ambient Temperature
Humidity
Storage Temperature
Location
Elevation
Vibration
Temperature during shipping (for short period)
† For details, refer to "Reducing motor noise or leakage current (n080)" on page 57.
3-
20P1
20P2
B0P1
B0P2
RUN and ALARM provided as standard LED's
Available to monitor frequency reference,
output frequency, output current
Main circuit: screw terminals
Control circuit: plug-in screw terminal
100m (328ft) or less †
Open chassis IP20, Open chassis IP20 (Top-closed type),
or enclosed wall-mounted NEMA 1 (TYPE 1)
Cooling fan is provided for the following models:
200V, 0.75kW or larger inverters (3-phase)
200V, 1.5kW or larger inverters (single-phase)
Other models are self-cooling
Open chassis IP20
Open chassis IP20 (Top-closed type) and enclosed
wall-mounted NEMA 1 (TYPE 1) : -10 to +40°C (14 to 105°F)
95%RH or less (non-condensing)
-20 to +60°C (-4 to 140°F)
Indoor (free from corrosive gases or dust)
1000m (3280ft) or less
Up to 9.8m / S
(1G) at 10 to less than 20Hz,
2
up to 2m / S
(0.2G) at 20 to 50Hz
2
200V single- / 3-phase
20P4
20P7
21P5
B0P4
B0P7
B1P5
: -10 to +50°C (14 to 122°F )
(not frozen)
22P2
24P0
B2P2
B4P0
147