Section 5 • Fault Codes
Load Sense System Fault Codes
Error Source 32, Boom Angle Safety Sensor (C141PBS)
Error Type
ID Name
ID
5
Sensor tolerance fault
11 Output short high
12 Value too high
15 Value too low
16 Output short low
17 Not calibrated
18 Just calibrated
21 Inconsistent
5 - 26
Condition
Name
Power relays disengaged.
Power relays disengaged.
Boom angle sensor
wiring open or shorted
to voltage.
Power relays disengaged.
Boom angle sensor wiring
open or shorted to voltage
OR sensor is out of
operating range.
Power relays disengaged.
Boom angle sensor wiring
open OR shorted to ground
OR sensor is out of
operating range.
Power relays disengaged.
Boom angle sensor wiring
open OR shorted to ground.
Boom range of
motion is limited.
Used to clear
diagnostic codes.
Checks operational
and safety sensor
values against
each other.
S-60 • S-65 • S-60 TRAX • S-65 TRAX
S-60 HC • S-60X • S-60XC
Solution
Repair wiring and/or connections OR
replace boom angle sensor and calibrate
overload system.
Repair wiring and/or connections
OR replace boom angle sensor
and calibrate overload system.
Repair wiring and/or connections
OR adjust or replace boom angle sensor
and calibrate overload system.
Repair wiring and/or connections
OR adjust or replace boom angle sensor
and calibrate overload system.
Repair wiring and/or connections
OR replace boom angle sensor
and calibrate overload system.
Calibrate the platform load sense
system.
Self-clearing.
Repair wiring and/or connections
OR replace boom angle sensor and
calibrate overload system.
December 2013
Part No. 147753