Section 5 • Fault Codes
Load Sense System Fault Codes
Error Source 22, String Potentiometer Safety Sensor (C167PSL)
Error Type
ID Name
5
Sensor tolerance fault
11 Output short high
12 Value too high
15 Value too low
16 Output short low
17 Not calibrated
18 Just calibrated
21 Inconsistent
5 - 24
Condition
Power relays disengaged.
Power relays disengaged.
String potentiometer
wiring open or shorted
to voltage.
Power relays disengaged.
String potentiometer
wiring open or shorted
to voltage.
Power relays disengaged.
String potentiometer
wiring open OR
shorted to ground OR string
potentiometer is faulty.
Power relays disengaged.
String potentiometer
wiring open OR
shorted to ground.
Boom range of motion
is limited.
Used to clear
diagnostic codes.
Checks operational
and safety sensor
values against each other.
S-60 • S-65 • S-60 TRAX • S-65 TRAX
S-60 HC • S-60X • S-60XC
Solution
Repair wiring and/or connections OR
replace string potentiometer and calibrate
overload system.
Repair wiring and/or connections OR
replace string potentiometer and
calibrate overload system.
Repair wiring and/or connections OR
replace string potentiometer and
calibrate overload system.
Repair wiring and/or connections OR
replace string potentiometer and
calibrate overload system.
Repair wiring and/or connections OR
replace string potentiometer and
calibrate overload system.
Calibrate the platform load
sense system.
Self-clearing.
Repair wiring and/or connections OR
replace string potentiometer and
calibrate overload system.