Genie S-60 TraX Service Manual page 121

Hide thumbs Also See for S-60 TraX:
Table of Contents

Advertisement

December 2013
2 Remove all weight, tools and equipment from
the platform.
Tip-over hazard. Failure to remove
all weight, options, accessories
and/or tools from the platform or
subtracting the weight of those
items from the test weights, will
result in the platform load sense
system not calibrating correctly.
This will allow too much weight to
be added to the platform which will
result in the machine tipping over.
3 Open the ground control box and locate the
calibration toggle switch near the relays.
Note: If either the operational and/or safety
controller has been replaced or if the software has
been updated, restore the system to the default
settings and then continue to step 4. See How to
Restore the Default Settings. Otherwise, continue
to step 4 to enter calibration mode.
4 Turn the key switch to ground control and pull
out the red Emergency Stop button to the on
position.
Result: The alarm sound for approximately
2 seconds.
How to Restore the System
Default Settings
1 Turn the key switch to ground control and
pull out the red Emergency Stop button to
the on position.
Result: The alarm should sound a long tone.
2 Activate and hold the calibration toggle
switch for 5 seconds.
Result: The alarm should sound a tone for
1 second.
3 Push in the red Emergency Stop button to
the off position.
Part No. 147753
5 Activate and release the calibration toggle
Note: Once calibration mode is entered and begun,
there is a 8 minute time limit between each
calibration step. If any one step passes the 8
minute time limit, the system will time out and the
calibration process will need to be repeated
beginning with step 1.
f
e
S-60 • S-65 • S-60 TRAX • S-65 TRAX
S-60 HC • S-60X • S-60XC
Section 4 • Repair Procedures
PLATFORM COMPONENTS
switch 3 times within 2 seconds after the alarm
sounds to enter calibration mode.
Result: The alarm should sound for 1 second
indicating the first calibration step was
accepted. The green LED on the operational
controller should be blinking fast and the red
LED should be blinking twice indicating that
step 2 of calibration is next.
Result: The alarm did not sound and the green
LED on the operational controller is not blinking
fast. Repeat this procedure beginning with
step 1.
d
a
green LED (operational control module)
b
red LED (operational control module)
c
operational control module
d
safety control module
e
red LED (safety control module)
f
green LED (safety control module)
a
b
c
4 - 15