Items
Power Supply
1 Power Requirement
2 Power Consumption
Environment
1 Temperature
Operation
Storage
Transport (Max. 72 hours)
2 Relative Humidity
Operation
Storage
Transport (Max. 480 hours)
Standards
1 PSTN
2 Safety
3 EMI
Construction
1 Dimensions (W x D x H)
2 Weight (Excluding paper)
Description
UF-490
108 - 132 VAC, 47 - 63 Hz, Single Phase 100 VAC Power Supply
198 - 255 VAC, 47 - 63 Hz, Single Phase 200 VAC Power Supply
Standby
Sleep Mode Less than 0.7 Wh
ES=On
ES=Off
Transmission
Reception
Copy
Maximum
Standby
Sleep Mode Less than 1.0 Wh
ES=On
ES=Off
Transmission
Reception
Copy
Maximum
50 to 95°F ( 10 to 35°C)
-4 to 104°F (-20 to 40°C)
-4 to 122°F (-20 to 50°C)
15 to 70% RH
5 to 85% RH
15 to 85% RH
FCC Part 68
Industry Canada No. CS-03
UL1950
CSA C22.2 No.950
ClassB computing device
in FCC Part 15
14.0 x 14.3 x 8.7 in
(355 x 364 x 220 mm)
16.1 lb
(7.3 kg)
6
5.5 Wh
± 25%
100 VAC Power Supply
17 Wh ± 25%
ES: Energy Saver
17 W
± 25%
450 W
± 15%
450 W
± 15%
470 W
6.0 Wh
± 25%
200 VAC Power Supply
17 Wh ± 25%
ES: Energy Saver
17 W
± 25%
460 W
± 15%
460 W
± 15%
470 W
Excluding projections
Excluding consumable
supplies and options
Remarks