Fq2-S@@-@@@ (Sensors With C-Mounts) - Omron FQ2-S/CH Series User Manual

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Important
• There is a certain amount of deviation among Sensors in the center of the optical axis. For this reason, when install-
ing the Sensor, check the center of the image and the field of view on the LCD monitor of the Touch Finder and in
the PC Tool.
Removal Procedure
1
Insert a flat-blade screwdriver between the Mounting Brack-
et and the Sensor case on either side and remove the
Mounting Bracket.

FQ2-S@@-@@@ (Sensors with C-mounts)

Installation Procedure
Directly Mounting the Sensor
1
Mount the Sensor with M3 screws.
Tightening torque: 0.54 N·m
Effective depth of mounting holes: 4 mm
Important
Refer to the dimension drawings in the appendix for the positions of
the screw holes.
Mounting the Sensor to the Base
1
You can attach the mounting base to the bottom, top, left,
or right surface.
(Recommended mounting screw tightening torque:
0.54 N·m)
Tightening torque: 0.54 N·m
Effective depth of mounting holes: 4 mm
2
Mount the Sensor with M3 screws.
Tightening torque: 0.54 N·m
Effective depth of mounting holes: 4 mm
40
Installation
Mounting
Bracket
FQ2-S/CH User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-s seriesFq2-ch series

Table of Contents