Errors - Omron FQ2-S/CH Series User Manual

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Measurement Data That Can Be Logged
The following values can be logged as measurement data.
Parameter
Range of value
Judgement
0: Judgement is OK
−1: Judgement is NG
−13: Teaching not performed error
−14: Figure not registered error
−15: Out of range error
Correlation
0 to 100
−99999.999 to 99999.999
Position X
−99999.999 to 99999.999
Position Y
−180 to 180
Angle
Count
0 to 32
*
When logging data is output, the data is output in the order of the above table.
If more than one item is stored, results are output for each model.
7-6 Logging Measurement Data and Image Data: p. 267

Errors

Errors in Teaching
A teaching error message will appear if the contrast of the image within the model registration region is too low.
Select a region with a larger contrast between light and dark areas compared to the region that was registered
as the model and re-register it as the model.
FQ2-S/CH User's Manual
Description
This is the measurement judgement results.
This is the measured correlation.
This is the measurement position X.
This is the measurement position Y.
This is the measurement angle.
This is the number of models found.