Unstable Reading Results

Reading Is Unstable Due to Low Contrast
Adjust the brightness to improve the contrast of the bar code.
Adjusting the Brightness: p. 67

Outputting Read Characters to an External Device

After a measurement, you can automatically output the character string that was read with the barcode
inspection item to a PLC or other external device. The character strings are output after outputting the output
data (output data settings 0 to 31), such as the inspection item parameters and calculation result.
Refer to the description for the communications format for the setting procedure and output specifications to
output the character string.
Vision Sensor FQ2-S/CH Series User's Manual for Communications Settings (Cat. No. Z338)
• Section 2 Controlling Operation and Outputting Data with a Parallel Connection
• Section 3 Controlling Operation and Outputting Data with an Ethernet Connection
• Section 4 Controlling Operation and Outputting Data with an RS-232C Connection
Note
The read character string is output after the other output data (data 0 to 31 in the output data settings) after the mea-
surement, such as the inspection item parameters and calculation results.
Refer to the following section for the location of the output area for the character string and other details.
Vision Sensor FQ2-S/CH Series User's Manual for Communications Settings (Cat. No. Z
Section 1 Overview of Communication Specifications

Measurement Data That Can Be Used for External Outputs and Calculations

Expression text
Data name
string
JG
Judgment
IN
Index
N
Num. of characters
FQ2-S/CH User's Manual
Description
This is the judgment result.
The verification result (master data No.) is out-
put.
The number of characters read is output.
338)
Data range
−2: No judgment (not measured),
0: Judgment is OK,
1: Judgment is NG,
−16: Measurement timeout error
−2: Verification OFF, or reading error
−1: Verification is NG,
0 to 31: Master data No.
0 to 1024