Shape Search Ii (Fq2-S1/S2/S3 Series Or Fq2-S4 Series Only) - Omron FQ2-S/CH Series User Manual

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

External
Category Data name
refer-
ence
number
700
Display
Correlation display
settings
701
Position X display
702
Position Y display
703
Measurement angle
display
704
Density deviation dis-
play
800
Mea-
Position X display pat-
sure-
tern
ment
801
Position Y display pat-
result
tern
display
802
Measured angle display
pattern
1000+N
Mea-
Sub-region correlation
(N=0 to
sure-
N
99)
ment
result
1100+N
Sub-region density
(N=0 to
deviation N
99)

Shape Search II (FQ2-S1/S2/S3 series or FQ2-S4 series only)

External
Category Data name
refer-
ence
number
0
Mea-
Judgement
sure-
ment
result
5
Correlation
6
Position X
7
Position Y
8
Angle
374
External Reference Parameters
Setting/Acqui-
Data range
sition
Setting/Acqui-
0: Display, 1: Do not display 0
sition
Setting/Acqui-
0: Display, 1: Do not display 0
sition
Setting/Acqui-
0: Display, 1: Do not display 0
sition
Setting/Acqui-
0: Display, 1: Do not display 0
sition
Setting/Acqui-
0: Display, 1: Do not display 0
sition
Setting/Acqui-
0: Absolute value, 1: Rela-
sition
tive value
Setting/Acqui-
0: Absolute value, 1: Rela-
sition
tive value
Setting/Acqui-
0: Absolute value, 1: Rela-
sition
tive value
Acquisition
0 to 100
only
Acquisition
Sub-region density devia-
only
tion N
Setting/Acqui-
Data range
sition
−2: No judgement (not
Acquisition
only
measured),
0: Judgement is OK,
−1: Judgement is NG,
−13: Teaching not per-
formed error,
−14: Figure not registered
error,
−15: Out of range error
Acquisition
0 to 100
only
−99,999.9999 to
Acquisition
only
99,999.9999
−99,999.9999 to
Acquisition
only
99,999.9999
−180 to 180
Acquisition
only
Default
Expres-
Logged data/
sion text
Judgement
string
parameter
---
---
---
---
---
---
---
---
---
---
0
---
---
0
---
---
0
---
---
0
CRN
---
0
DVN
---
Default
Expres-
Logged data/
sion text
Judgement
string
parameter
−2
JG
Logged data
0
CR[0] to
Logged data
CR[31]
0
X[0] to
Logged data
X[31]
0
Y[0] to
Logged data
Y[31]
0
TH[0] to
Logged data
TH[31]
FQ2-S/CH User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-s seriesFq2-ch series

Table of Contents