Parameter
Y coordinate of the partial input start
point
Y coordinate of the partial input end
point
Note
• The minimum input widths are 16 for the X axis and 8 for the Y axis.
• The values of the monitor display positions are displayed for the coordinates in the measurement results.
• The coordinate values will not change as a result of the partial input settings.
Important
If you use partial input, perform teaching again. Partial input on the X axis is supported only by the FQ2-S3@-
@@@@/FQ2-S4@@@@@/FQ2-S4@@@@@-M.
• FQ2-S1/S2/CH
[Image] − [Camera setup]
1
Press [
] – [Partial input] on the right side of the dis-
play.
2
Change the input size.
3
Press [OK].
4
Press [Back].

Changing the Image Input Mode

Pixel sampling can be applied to the input image to reduce image input time.
[Image] − [Camera setup] −
Parameter
Setting
Image Input
High-speed or Standard
Mode
Default: Standard
Important
If you change the image input mode, perform teaching again.
230
Shortening the Measurement Takt Time
Setting
• FQ2-S@@@@@@/FQ2-S@@@@@@-M
Range: 0 to 472, Default: 0
• FQ2-S@@@@@@-08@
Range: 98 to 918, Default: 98
• FQ2-S@@-@@@
Range: 0 to 1,016, Default: 0
• FQ2-S@@@@@@/FQ2-S@@@@@@-M
Range: 7 to 479, Default: 479
• FQ2-S@@@@@@-08@
Range: 105 to 925, Default: 925
• FQ2-S@@-@@@
Range: 7 to 1,023, Default: 1,023
− [Image input mode]
Description
Specify the partial input range along the Y
axis.
Description
Pixel sampling can be applied to the input image to
reduce image input time.