Checking Recent Measurement Trends (Recent Results Logging) - Omron FQ2-S/CH Series User Manual

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Checking Recent Measurement Trends (Recent Results Logging)

The most recent measurement results can be logged inside the Sensor.
Even if data is not logged in external memory, such as an SD card, trends in measurement results can be
easily checked on the Touch Finder.
However, if the power supply is turned OFF, this data will be lost.
Recent measurement results
Measurement data, Calculation result: Most recent 1,000 values
Image data: Most recent 20 images
Sensor
Statistical Data
Setting Logging Conditions
Use the following procedure to set the conditions for the measurement data, image data, and statistical data
that will be logged.
Some of these operations and settings are the same as for file logging.
Setting Logging Conditions: p. 268
Item
Description
Statistical data
Statistical data, such as the number of measurements, the number of NG overall judgements, and the
NG rate, since the power supply was turned ON will be logged.
Logging image (image data) These are the same as for file logging.
Logging data (measurement
data)
Note
The logging parameters for image data and measurement data are the same as those for file logging.
FQ2-S/CH User's Manual
Touch Finder
• ON: Statistical data will be displayed (default).
• OFF: Statistical data will not be displayed.
Trend monitor
Histogram
Statistical data
Logging Measurement Data and Image Data
Trend Monitor:
p. 241
Histograms:
p. 242
Statistical data:
p. 238
273