Your XP4000 Series unit has a serial port on the front panel that is available for
the connection of a printer or similar device at the local workstation. This port
can also be used to obtain a configuration report of your XP4000 system or to
download system enhancements and new product features that you have received
from Cybex. This section covers these advanced applications of the serial port
and how you may utilize them through the XPLU or LCI modules of your
XP4000 system. If you have XPRB modules in your system, see the next
section, "Serial Port Advanced Operations (for XPRB Modules)."
The following procedures can be accomplished in one of two ways. If one of
your attached computers has a serial port and terminal emulation software, you
may run the configuration/upgrade procedures from this machine. If none of the
attached computers in your XP4000 system meet these requirements, then you
must have use of a computer not currently attached to your XP4000 system with
terminal emulation software and a serial port. A null modem (cross over) cable
will also be needed with this setup.
If you are working with a computer in the XP4000 system, make this the active
channel now. Otherwise, connect the null modem cable between the serial port
of your unattached computer and the serial port on the front panel of the XP4000
Series unit. Run your terminal emulation software as usual. Adjust your setup
to the following:
1200 - 19200 (except 14400) Baud,N,8,1
Enter the hotkey sequence below that applies to your configuration.
Key Sequence
<CM>ZF<Enter>
<CM>ZB<Enter>
<CM>ZS<Enter>
<CM>ZQ<Enter>
The interface on the XP4000 Series unit will sync up to the rate that you want
to run at. Press the ENTER key when you are prompted to do so. The
Configuration/Upgrade main menu shown below should now be on your screen.
1) Display chassis configuration
2) Download local to remote Flash ROM
3) Download Serial Port to Flash ROM
Q) Quit
Your choice:
Condition
If you are connected through an unattached computer to
the Front panel serial port or a high speed serial port from
an XPDU.
If you are connected through an attached computer
If you are connected with an unattached computer
through the serial mouse port of an XPLU/XPDU module.
Quits the Configuration Menu
Main Menu
106
No flow control