Determine which fan to replace by checking the LEDs on the fans. The front fans,
center fans, and rear fans are installed differently from each other. This section
contains separate instructions for each group of fans.

Replacing a front fan

Complete the following steps to replace front fan (blower) 5 or 6:
1. Review the information in "Safety" on page v, "Installation Guidelines" on page 9,
2. Remove the server cover (see "Removing the server left-side cover and bezel
3. Press the orange fan-release latch in the direction indicated by the arrow.
4. Pull the fan out of the server.
5. Align the two tabs on the replacement fan with the notches in the server and
6. Verify that the FAN LED on the diagnostic LED panel (see the Hardware
7. Reinstall the server cover (see "Installing the server bezel and left-side cover

Replacing a center fan

Complete the following steps to replace center fan 3 or 4:
1. Review the information in "Safety" on page v, "Installation Guidelines" on page 9,
2. Remove the server cover (see "Removing the server left-side cover and bezel
3. Press the orange fan-release latch in the direction indicated by the arrow; the
4. Pull the fan out of the server.
5. Press the orange fan-release latch in the direction indicated by the arrow and
6. Verify that the FAN LED on the diagnostic LED panel (see the Hardware
7. Reinstall the server cover (see "Installing the server bezel and left-side cover
and "Handling static-sensitive devices" on page 10.
(tower model)" on page 15 or "Removing the server top cover and bezel (rack
configuration)" on page 17).
Attention:
To ensure proper system cooling, do not remove the server cover
for more than 30 minutes during this procedure.
press the fan into the corresponding connector. Press the front edge of the fan
to engage the latch fully and secure the fan in the server.
Maintenance Manual and Troubleshooting Guide on the IBM xSeries
Documentation CD) is not lit. If the FAN LED is lit, reseat the fan.
(tower model)" on page 62 or "Installing the server bezel and top cover (rack
configuration)" on page 65).
and "Handling static-sensitive devices" on page 10.
(tower model)" on page 15 or "Removing the server top cover and bezel (rack
configuration)" on page 17).
Attention:
To ensure proper system cooling, do not remove the server cover
for more than 30 minutes during this procedure.
latch will rotate downward.
open the latch; then, slide the replacement fan into the server. Press the latch
up to snap it into place and secure the fan in the server.
Note: When you slide the fan into the server, make sure the orange fan-release
latch is at the top.
Maintenance Manual and Troubleshooting Guide on the IBM xSeries
Documentation CD for the location of the LED) is not lit. If the FAN LED is lit,
reseat the fan.
(tower model)" on page 62 or "Installing the server bezel and top cover (rack
configuration)" on page 65).
Chapter 2. Installing options
57

Advertisement

Table of Contents
loading

Table of Contents