4219/4229 Expansion Zones

1. Connect each module to the control's keypad
terminals.
2. Assign the module a device address of 08
using its DIP switches. The device address
determines the zone numbers being used, as
shown below.
Expander Module Addresses
Zones...
Device Address...
17-24
08
3. Connect sensors to the module's loops.
4. If using relays with the 4229, connect the
desired field wiring to the unit's relay
contact terminals.
RELAY
CONNECTOR
RLY
RLY
2
1
REED
(TAMPER)
RELAYS OFF
SWITCH
ZONES
Figure 7. Wiring Connections, 4219 & 4229 (4229 shown)
RELAY
DIP SWITCH
2
FOR SETTING ADDRESS
AND ZONE "A" RESPONSE
RELAY
1
NO C NC
TAMPER JUMPER POSITION
4229 IN CABINET
(NOT TAMPER)
4229 REMOTE
(TAMPER PROTECTED)
1
2
3
4
5
6
A
B
C
D
Mounting and Wiring the Control
Notes
• Supports up to 8 expansion zones (NO or NC)
using 4219/4229 Zone Expander Modules as
follows:
• Use 1000 ohm end-of-line resistors at the end
of loops connected to the 4219/4229 modules.
(End-of line resistors used on the control
terminals are 2000 ohms.)
• Expansion zones have normal response time
(400–500 msec), except zone connected to each
module's loop "A," which can be set for fast
response† (10–15 msec).
† Do not use fast response in Western Europe;
fast response is not permitted by
EN50131-1/prEN50131-3.
4229
EITHER OR BOTH CAN BE USED
TB2
4-PIN CONSOLE PLUG
4
4
3
2
TB1
1
7
8
9
10
11
12
TERMINATE EACH
PROGRAMMED ZONE
WITH 1000 OHM (1K)
END-OF-LINE RESISTOR
(EACH ZONE'S MAX.
LOOP RESISTANCE
300 OHMS + EOL)
E
F
G
H
TERMINALS ON
CONTROL PANEL
GRN
DATA OUT (>)
(TERM 6)
TO CONTROL
BLK
3
(–) GROUND
(TERM 4)
RED
(+) 12VDC
(TERM 5)
2
DATA IN (<)
YEL
FROM
1
(TERM 7)
CONTROL
4229-002-V0
2-9