Honeywell ADEMCO Vista-12C Installation And Setup Manual page 61

Table of Contents

Advertisement

PROMPT
17 INPUT S/N:
L
A 0 2 2 - 4 0 6 4
1
17 INPUT S/N
L
A 0 2 2 - 4 0 6 4
?
yy
17 INPUT S/N
L
A 0 2 2 - 4 0 6 4
1
VALID ENTRIES
Serial number Entry
and Loop Number Entry
see explanation
[∗] to continue
Loop Number Change
[∗] to continue
Enroll Summary
[∗] to continue
Menu Mode Programming
EXPLANATION
Used only when enrolling wireless transmitters.
a. Transmit two open/close sequences. If using a
button-type transmitter, press and release the
button twice, but wait about 4 seconds before
pressing the button the second time.
OR
b. Manually enter the 7-digit serial number
printed on the label of the transmitter. Then
press the [∗] key – the cursor will move to the
"L" position. You can edit the loop number, if
necessary. When the loop number is
acceptable, press [∗].
c. Press key [C] to copy the serial number
previously enrolled (used when programming a
transmitter with several input loops).
NOTE: If the [C] key is used to copy the
previously enrolled serial number, the cursor will
move to the Loop column (L) with the previous
serial number displayed, and display a
highlighted question mark for the loop number.
Enter the loop number and press [∗]. The system
will now check for a duplicate serial/loop number
combination.
If the serial/loop number combination is not a
duplicate in the system, a display showing the
serial number and loop number entry will appear.
To Delete an Existing Serial Number: Enter 0
in the loop number field. The serial number will
change to 0's.
10 INPUT S/N:
L
A 0 0 0 - 0 0 0 0
0
If 0 was entered in error, simply re-enter the loop
number or press [#], and the serial number will
return to the display.