Loading Factory Defaults/Initializing for Download
To Load Default Entries
To Initialize Download ID
Do not press
previously—data already programmed into the system will be changed!
4
Exiting the Programming Mode
Prevent installer code
reentry
Allow installer code reentry
Data Field, System, and Zone Defaults: The control has two sets of
default entries. Default values are listed in the Programming Guide.
Press ∗97 while in Program Mode, then press 1 or 2 to load the desired
set of factory defaults (default set 1 or default set 2). This resets all
data fields to the respective default set values.
User Code Defaults: To reset only the user codes to default values,
press ∗97, then press 3.
Press ∗96 while in Program Mode. This initializes the system for
downloading and resets all the subscriber account numbers and CSID.
97 to load defaults if any programming has been done
Press ∗98. Exits Programming Mode and prevents re-entry by:
Installer Code + [8] + [0] + [0]. To enter the programming mode if ∗ 98
was used to exit, you must first power the system down. Then power up
again, and press [∗] and [#] at the same time, within 50 seconds of
powering up.
Press ∗99. Exits Programming Mode and allows re-entry by:
Installer Code + [ 8] + [0] + [0] or by: Pressing [∗] and [#] at the same
time, within 50 seconds of power-up.
Mounting and Wiring the Control
3-9