Honeywell ADEMCO Vista-12C Installation And Setup Manual page 73

Table of Contents

Advertisement

"A"
PROMPT
01 Zn List
1
"B"
01 Enter Zn type
Perimeter
03
VALID ENTRIES
If zone list was selected, this screen appears. Otherwise skip to the
Zone List
next row.
01-12 = zone
list
Enter the desired zone list number associated with this output
number.
[∗] to continue
NOTE: Zone lists 09-12 can be used in output definitions if not
used for paging or for exit zone definition.
Press [ ∗ ] to continue.
Enter the zone list event that will activate this output.
Enter Event
Alarm
NOTE: For alarm, fault, and trouble, an event on ANY zone in the
list activates the output.
Press [ ∗ ] to continue and skip to the "Output Action" prompt.
Zone Type
If zone type was selected, this screen appears. Otherwise skip to
the next row.
see list at right
Enter the desired zone type associated with this output number.
See below for a list of available zone types.
CHOICES FOR ZONE TYPES:
00 = Not Used
01 = Ent/Exit #1
02 = Ent/Exit #2
03 = Perimeter
04 = Interior Follower 09 = Fire
CHOICES FOR SYSTEM OPERATION:
20 = Arming–Stay
21 = Arming–Away
22 = Disarming
31 = End of Exit Time
32 = Start of Entry Time 41 = **AC Mains Failure
33 = Any Burglary Alarm 42 = **System Battery Low 68 = Telecom Line Cut
** Use 0 (Any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
† Use *57 Menu Mode to assign the function key (function "07").
Note: In normal operation mode:
Code + # + 7 + NN Key Entry starts Device NN.
Code + # + 8 + NN Key Entry stops Device NN.
Enter the partition in which this zone type will occur.
01 Partition
Any partition
Press [ ∗ ] to continue and skip to the "Output Action" prompt.
Menu Mode Programming
EXPLANATION
0 = restore; 1 = alarm;
1
2 = fault; 3= trouble
05 = Trouble Day/Alarm Night 16 = Fire w/verification
06 = 24 Hr Silent
07 = 24 Hr Audible
08 = 24 Hr Aux
10 = Interior w/Delay
12 = Monitor Zone
14 = Gas
36 = **At Siren Timeout***
38 = Chime
39 = Any Fire Alarm
40 = Bypassing
43 = Comm. Failure
52 = Kissoff
0 = any partition; 1 = partition 1;
0
2 = partition 2; 3 = partition 3
23 = No Alarm Response
24 = Silent Burglary
77 = Keyswitch
81 = AAV Monitor Zone
82 = Blockschloss
90-93 = Configurable
54 = Fire Zone Reset
58 = Duress
60 = AAV
66 = Function Key†
67 = Siren Fail
78 = Keyswitch Red LED
79 = Keyswitch Green LED
80 = Tamper Fault
5-17