Backup Battery; Earth Ground - Honeywell ADEMCO Vista-12C Installation And Setup Manual

Table of Contents

Advertisement

Installation and Setup Guide

Backup Battery

1. Place the 12-volt backup battery in the cabinet.
2. After all connections to the control are completed
and AC mains power has been applied, connect the
red and black flying leads on the control board to the
battery. Do not attach these leads to the battery
terminals until all connections are completed.
Battery Saver Feature: The battery will disconnect
from the system after its voltage decreases below
9VDC. This assists the control panel in recharging the
battery when AC is restored.

Earth Ground

Metal Cold Water Pipe or Earth Ground Rod:
Use a non-corrosive metal strap (copper is
recommended) firmly secured to the pipe/rod to which
the ground lead is electrically connected and secured.
Notes
• This product has been designed and tested to ensure
its resistance to damage from generally expected levels
of lightning and electrical discharge, and does not
normally require an earth ground.
DEVICE
6128RF Keypad/Transceiver
6150RF Keypad/Transceiver
6148 Fixed-Word Keypad
6164 Keypad w/4-Zone Expander
and Relay
6150 Fixed-Word Keypad
6160 Alpha Keypad
6150V Fixed-Word Display Voice
Keypad
6160V Alpha Display Voice Keypad
5881RF Receiver
5883 RF Transceiver
5882EU Transceivers
4219 Zone Expander
4204 Relay Unit
4229 Zone Expander/Relay Unit
TeleCommand
*
*
If using wired devices such as PIRs or Dual Tecs, refer to the specifications for that particular unit's current drain.
‡ Figures are for relays OFF/relays ON.
2-6
AUXILIARY DEVICE CURRENT DRAIN WORKSHEET
CURRENT
90mA standby/120mA alarm
80mA standby/105mA alarm
30mA standby/55mA alarm
115mA standby/190mA alarm
40mA standby/90mA alarm
40mA standby/150mA alarm
60mA standby/160mA alarm
60mA standby/190mA alarm
35mA
80mA
60mA nominal, 85mA peak
35mA
15/180mA ‡
35/100mA ‡
55mA (standby)
119mA (local phone)
85mA (remote phone)
(Current available from Aux. terminals = 600 mA max.)
Notes
IMPORTANT: The panel will not power
up initially on battery power only. You
must plug the transformer in first, and
then connect the battery.
• If an earth ground is desired for
additional protection in areas of severe
electrical activity, terminal 25 on the
control board, or the cabinet, may be
used as the ground connection point.
The examples of good earth grounds
listed at the left are available at some
installations.
# UNITS
TOTAL =
TOTAL CURRENT