Installation and Setup Guide
FIELD
TITLE and DATA ENTRIES
Option Selection
*91
0 = none
4 = using Audio Alarm Verification (AAV) unit
8 = Enable Exit delay restart/reset ††
Multiple choice example: for both AAV and
Exit delay restart, enter # + 12 (4 + 8).
Telecom Monitor Enable
*92
Entry 1–Timeout:
0 = disabled
1-15 = 1 minute to 15 minutes respectively
(2 = 2 min, 3 = 3 min, etc.; # + 10 =10 min,
# + 11 = 11 min, # + 12 = 12 min,
# + 13 = 13 min, # + 14 = 14 min,
# + 15 = 15 min)
Entry 2–Display/Sound:
0 = keypad display only when phone line is
faulted.
1 = keypad display plus keypad trouble
sound when line is faulted. Each
partition turns off its own trouble sound.
No automatic timeout.
2 = Same as "1" plus programmed output
device STARTS. If any partition is
armed, external sounder activates.
External sounder will be turned off by
normal siren timeout or by security code
plus OFF from any partition (it does not
have to be the one that was armed).
No. of Reports In Armed Period
*93
per Zone (Intermittent Sensor
Suppression)
0 = unlimited number of reports
1 – 6 = 1 – 6 report pairs per zone per
armed period

Download Phone Number

*94
Enter up to 30 digits as follows: 0–9, # +11
for "∗", # + 12 for "#", # + 13 for a pause.
4-12
EXPLANATION
Select the desired options by adding the values of each
desired option.
††"Exit Delay Restart/reset" option allows use of the [∗]
key to restart the exit delay at any time when the
system is armed STAY or INSTANT. This feature also
enables automatic exit delay reset, which resets exit
delay if the entry/exit door is re-opened and closed
before exit delay time expires after arming AWAY or
MAXIMUM.
IMPORTANT: AAV should not be used when Paging
or Alarm Reports are sent to a secondary number
unless the monitoring zone option is used (which
pauses calls). Otherwise, the call to the secondary
number by the communicator after the alarm report
will prevent the AAV from taking control of the
telephone line, and the AAV "Listen in" session cannot
take place.
Entry 1: Sets the length of time a phone line fault
must remain after detected before the second digit
option is activated.
Entry 2: Selects the desired phone line fault response.
Option 2 may be used even if a relay unit or Powerline
carrier device is not connected to the control.
Programmed Output Device must either be
programmed to be STOPPED in field ∗80 or STOPPED
by entry of [security code] + [#] + 8 + device number.
Partition in ∗80 should be set to "0," for STOP.
This option can be used to limit the number of
alarm/alarm restore messages per zone sent to the
central station in an armed period.
Enter the phone number of the downloading computer.
Do not fill unused spaces. End field by entering ∗. To
clear entries from field, press ∗94∗.