Installation and Setup Guide
PROMPT
Zn ZT P RC HW: RT
01 09 1 10
EL
1
Zn ZT P RC IN: L
10
– :
Zn ZT P RC IN: L
10
00 1 10 RF 1
5-8
VALID ENTRIES
Summary Screen
01-06, 9-24, 49-64 = zone
number
00 = quit
[∗] to continue
OR
[D] to go to prompts for wireless
key programming templates
Zone Programming
ZT = see Zone Type chart
shown in *56 Menu Mode
"Zone Type" prompt
P =
partition 1, 2, 3 (common)
RC = 0-9
(cannot enter hex report
codes; use *56 mode to
enter hex codes)
IN = input type
L =
loop number
[∗] to continue
EXPLANATION
A summary screen will appear, showing zone
1's currently programmed (or default) values.
Enter the zone number being programmed,
then press [∗], which displays a summary
screen for that zone. See next prompt (in this
example, zone 10 is being entered).
If programming a wireless key, press the [D]
key then skip to the Wireless Key
Programming Templates section following
this section. When [D] is pressed, you can
choose from a series of preset templates for
easy programming of wireless key zones.
When all zones have been programmed, press
"00" at this prompt to quit this menu mode.
A summary screen with the selected zone's
current programming appears.
Begin programming zone information as
follows:
• Enter Zone Type (ZT), Partition (P), Report
Code (RC), and Input Device Type (IN)*
sequentially, but not the Loop No. (L).
NOTE: Hexadecimal report codes A
through F cannot be entered in the Expert
Mode. Hexadecimal report codes of A
through F can only be entered using the
Zone Programming Procedure (*56 Menu
mode).
• Use the [A] (Advance) and [B] (Back) keys
on the keypad to move the cursor within
the screen.
• Use the [C] key to copy the previous zone's
attributes.
Press [∗] to save the programming and
continue to the serial number/loop number
prompt. If needed, you can press the [#] key
to back up without saving.
*
If HW (basic wired) or AW (Auxiliary) is
entered for Input Device Type, the next
screen will be similar to the prompt shown,
except that HW or AW will be displayed
under "IN".
If RF, BR, or UR is entered, a prompt for
Serial and Loop number will be displayed, as
follows.