Installation and Setup Guide
Various System Trouble Displays (cont'd.)
no display
no display
Comm. Failure
FC
Open Circuit
OC
Long Rng Trbl
bF
Bell Failure
70
RCVR Jam
90
KEYPAD LOW BAT
00 BAT
Phone Okay
Cd
Dialer Off
dO
Test in Progress
dd
Upload Completed
dC
Upload Failed
dF
6-12
Power Failure
If there is no keypad display at all and the LEDs are unlit, operating
power (AC and battery) for the system has stopped and the system is
inoperative.
If the message "AC LOSS" (Alpha display keypads) or "NO AC"
(Fixed-Word display keypads) is displayed, the keypad is operating on
battery power only.
If the battery standby capacity is used up during a prolonged AC
power outage, the control's power will shut down to minimize deep
discharge of the battery.
A communication failure has occurred.
The keypad is not receiving signals from the control and sees an open
circuit.
Backup Alternative Communication Media communication failure.
Siren supervision failure.
RF jam detected.
Wireless keypad low battery
The dialer test has been successful (CID code 601).
The dialer is disabled.
Walk test mode is active(CID code 607).
The upload or download session was completed.
The upload or download session failed before completion.