SL 750 SHIVER
•
Loosen the clamp to slide off the bleed
pipe.
•
Lift the filter casing and working on
both cylinders, loosen and move the
clamp and slide off the oil vapour re-
covery pipe.
•
Working on the left side, disconnect the
two control unit connectors.
CAUTION
THE CONNECTORS ARE MARKED BY THE
LETTERS "V" (VEHICLE) AND "E" (ENGINE).
DO NOT INTERCHANGE THEM WHEN REFIT-
TING.
•
Undo and remove the screw and re-
move the ground lead.
Bodywork