V-Link Settings; Rs-232C Settings - Roland M-200i V-mixer Owner's Manual

Live mixing console
Hide thumbs Also See for M-200i V-mixer:
Table of Contents

Advertisement

Remote

V-LINK settings

1.
Access the REMOTE screen.
2.
Select "V-LINK" and press [ENTER].
The V-LINK screen appears.
V-LINK
1
This turns the V-LINK function on/off.
-
SOURCE 1-16
17
2
These access the V-LINK SOURCE1 to 16 screens (p. 110).
V-LINK SOURCE screens
At the V-LINK SOURCE1 to 16 screens, you can specify the
channels that correspond to V-LINK sources 1 through 8, and set
the maximum level and minimum level for each one.
1.
Access the V-LINK screen.
2.
Select the desired source from among SOURCE 1 to 16
and press [ENTER].
The V-LINK SOURCE screen is displayed.
You can make the settings for the items described below.
CHANNEL
1
This selects the channel that corresponds to the source.
MAX LEVEL
2
This specifies the level when the source level is at the
maximum (100%), in a range of -Inf dB to +10.0 dB.
MIN LEVEL
3
This specifies the level when the source level is at the
minimum (100%), in a range of -Inf dB to +10.0 dB.
110

RS-232C settings

1.
Access the REMOTE screen.
2.
Select "RS-232C RATE" and press [ENTER].
The RS-232C RATE screen appears.
3.
Select the RS-232C communication speed and press
[ENTER].
Select the value that matches the speed setting on your