The page includes the following fields:
Object
 Mode
 Ping PD IP Address
 Interval Time (10~300s)
 Retry Count (1~5)
 Action
 Reboot Time (30~180s)
Buttons
: Click to apply changes
: Click it to reset configuration which has not been saved yet.
Description
Allows user to enable or disable per port PD Alive Check function.
As default value all ports are disabled.
This coulumn allows user to set PoE device IP address here for system making ping
to the PoE device. Please be noticed that the PD's IP address must be set to the
same network segment with WGSW-48040HP PoE Switch.
This column allows user to set how long system should be issue a ping request to
PD for detecting PD is alive or dead.
Interval time range is from 10 seconds to 300 seconds.
This column allows user to set how many times system rerry ping to PD.
For example, if we set count 2, the meaning is that if system retry ping to the PD and
the PD doesn't response continuously, the PoE port will be reset.
Allows user to set which action will be apply if the PD witout any response.
WGSW-48040HP PoE Switch offers 3 actions as following.
PD Reboot: It menas system will reset the PoE port that connected the PD.
Reboot & Alarm: It means system will reset the PoE port and issue an
alarm message via Syslog, SMTP.
Alarm: It means system will issue an alarm message via Syslog, SMTP.
This column allows user to set the PoE device rebooting time, due to there are so
many kind of PoE device on the market and theyhave different rebooting time. The
PD Alive-check is not a defining standard, so the PoE device on the market doesn't
report reboots done information to WGSW-48040HP PoE Switch, so user has to
make sure how long the PD will be finished to boot, and then set the time value to
this column.
System is going to check the PD again according to the reboot time. If ou can not
make sure precisely booting time, we suggest you to set it longer.