Planet XGSW-28040HP User Manual page 109

L2+ 24-port 10/100/1000mbps 802.3at poe + 4-port 10g sfp+ managed switch with hardware layer3 ipv4/ipv6 static routing
Hide thumbs Also See for XGSW-28040HP:
Table of Contents

Advertisement

Hybrid
Port VLAN
Port Type
discarded
By default, all frames but frames classified to the Port VLAN (a.k.a.
Native VLAN) get tagged on egress. Frames classified to the Port
VLAN do not get C-tagged on egress
Egress tagging can be changed to tag all frames, in which case only
tagged frames are accepted on ingress
Hybrid ports resemble trunk ports in many ways, but adds additional port
configuration features. In addition to the characteristics described for trunk ports,
hybrid ports have these abilities:
Can be configured to be VLAN tag unaware, C-tag aware, S-tag
aware, or S-custom-tag aware
Ingress filtering can be controlled
Ingress acceptance of frames and configuration of egress tagging can
be configured independently
Determines the port's VLAN ID (PVID). Allowed VLANs are in the range 1
through 4095, default being 1.
■ On ingress, frames get classified to the Port VLAN if the port is configured as
VLAN unaware, the frame is untagged, or VLAN awareness is enabled on
the port, but the frame is priority tagged (VLAN ID = 0).
■ On egress, frames classified to the Port VLAN do not get tagged if Egress
Tagging configuration is set to untag Port VLAN.
The Port VLAN is called an "Access VLAN" for ports in Access mode and Native
VLAN for ports in Trunk or Hybrid mode.
Ports in hybrid mode allow for changing the port type, that is, whether a frame's
VLAN tag is used to classify the frame on ingress to a particular VLAN, and if so,
which TPID it reacts on. Likewise, on egress, the Port Type determines the TPID
of the tag, if a tag is required.
Unaware:
On ingress, all frames, whether carrying a VLAN tag or not, get classified
to the Port VLAN, and possible tags are not removed on egress.
C-Port:
On ingress, frames with a VLAN tag with TPID = 0x8100 get classified to
the VLAN ID embedded in the tag. If a frame is untagged or priority
tagged, the frame gets classified to the Port VLAN. If frames must be
tagged on egress, they will be tagged with a C-tag.
S-Port:
On ingress, frames with a VLAN tag with TPID = 0x8100 or 0x88A8 get
classified to the VLAN ID embedded in the tag. If a frame is untagged or
priority tagged, the frame gets classified to the Port VLAN. If frames must
be tagged on egress, they will be tagged with an S-tag.
109