14-1 Troubleshooting (Cont'd)
In the case of troubles occurring during operation of the GY-DV500, it performs a self-test to identify the cause and displays the
result in the form of an error code. The error code consists of the "main code" which indicates its contents and the "sub-code" which
indicates the details. Depending on the status of the GY-DV500 at this time, indications may also appear on the LCD display, the
WARNING indicator may activate and the alarm tone may be generated.
In the viewfinder, the "VTR WARNING (DEW)" indication appears when condensation is detected, and the "VTR WARNING (STOP)",
"VTR WARNING (HARD)" or "VTR WARNING (REW)" indication appears depending on the contents of the error code when some
of the other error codes are displayed.
VTR WARNING (HARD)
VTR WARNING (DEW)
Auto-OFF indicator:
Lights depending on the error code.
When this indicator lights, the
GY-DV500 will automatically stop
operation or eject the cassette. The
GY-DV500 does not accept any
operation.
WARNING indicator
Alarm Tone
Red. blinking
Continuous
Red, blinking
Intermittent
* In the Auto OFF status, it is impossible to operate the GY-
DV500. This condition can be cancelled by switching the
POWER switch OFF and then switching it ON again. If the
same problem occurs again after the power is turned ON,
there may be something wrong with the GY-DV500. Please
consult the person in charge of professional video equipment
at your nearest JVC-authorized service agent.
TALLY lamp
FILTER
1 3200k
2 5600k
3 5600k+ND
SHUTTER
MENU
AUTO IRIS
AUTO OFF
Display
"Error code"
• Automatically ejects the cassette. It can be inserted again.
"Error code"
• Automatically stops operation or ejects the cassette.
plus
"AUTO OFF"
"DEW "
• Dew condensation inside the unit.
WARNING indicator
OPERATE/WARNING
LIGHT
RESET
ON
OFF
MONITOR
SELECT
COUNTER
CTL
ALARM
TC
UB
STATUS
MONITOR
CH-1
AUDIO
CH-2
LEVEL
FULL AUTO BLACK
LOLUX
BACK L
STRETCH
NORMAL
NORMAL
SPOT L
COMPRESS
NG
POWER
ON
OFF
ALARM
tone
Dew condensation
indicator
DEW
Main code
Sub-code
GY-DV500 Operation
(Auto OFF) * The GY-DV500 does not accept any operation.
The GY-DV500 does not accept any operation until the DEW indicator
disappears from the display.
The GY-DV500 is a microcomputer-controlled piece of
equipment, which may malfunction due to external noise
or interference. In this case, set the POWER switch to OFF,
remove the lithium backup battery, and then set the
POWER switch to ON again after a few minutes.
14. OTHERS
TALLY
lamp
EARPHONE