Post Output; 11.3.1 Post Min Normal; Table 11-5 Post Min Normal Output Comparison - Sun Microsystems Ultra 25 Service Manual

Hide thumbs Also See for Ultra 25:
Table of Contents

Advertisement

11.3

POST Output

The contents of the POST output depends on the values of the diagnostic level and
output verbosity. For the examples in this section, the
workstation
1.
Note – The 0> that precedes the output text is the CPU identifier and indicates that
the output is from POST. The 1> indicates CPU 1. If you do not see these characters,
the output is from the OpenBoot PROM.

11.3.1 post min normal

The following is the output of POST with min diagnostic level and normal output
verbosity. The duration of POST was 90 seconds. The left column of the table is the
output. The right column describes what is happening. If the POST output from
your system does not match the output in the left column, use the information in the
right column to help diagnose the problem.
post min normal Output Comparison
TABLE 11-5
Output Displayed
ok post min normal
reset reason: 0000.0000.0000.0001
Fire TLU-A OE Error status: 0003.0100.0000.0100
@(#)OBP 4.21.x 2005/09/28 16:12 Sun Ultra 45 or Ultra 25
workstation
Clearing TLBs
Executing Power On Self Test
Q0>
0>@(#) Sun Ultra 45 POST 4.21.x 2005/10/13 16:57
/dat/fw/common-source/firmware_re/post/post-build-
4.21.x/Ultra/Ultra45/integrated
11-4
Sun Ultra 45 and Ultra 25 Workstations Service and Diagnostics Manual • May 2006
was configured with a single CPU and two 1-GByte DIMMs in slots 0 and
(firmware_re)
Sun Ultra 45 or Ultra 25
What Is Happening
User initiates POST from the
OpenBoot PROM ok prompt.
OpenBoot PROM prepares to run
POST.
POST build version and date is
displayed.
POST build path is displayed.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ultra 45

Table of Contents