iostat -En
c0t0d0
Model: ST3120026A
Size: 120.03GB <120031641600 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0
c0t2d0
Vendor: LITE-ON
Serial No:
Size: 0.00GB <0 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
9.5.2

prtdiag Command

The prtdiag command displays configuration and diagnostic information for a
system. The diagnostic information identifies any failed component in the system.
The prtdiag command is located in the /usr/platform/platform-name/sbin/
directory.
Note – The prtdiag command might indicate a slot number different than that
identified elsewhere in this document. This is normal.
9.5.2.1

Options

TABLE 9-3
help troubleshoot the Sun Ultra 45 or Ultra 25 workstation.
Options for
TABLE 9-3
Option
Description
No option
Lists system components.
Verbose mode. Displays the
-v
time of the most recent AC
power failure, the most recent
hardware fatal error
information, and (if applicable)
environmental status.
9-8
Sun Ultra 45 and Ultra 25 Workstations Service and Diagnostics Manual • May 2006
Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Product: COMBO SOHC-4832K Revision: O3K1
describes options for the prtdiag command and how those options can
prtdiag
Revision: 8.01
How It Can Help
Identifies CPU timing and PCI cards installed.
Provides the same information as no option. Additionally
lists fan status, temperatures, ASIC, and PROM revisions.