Brother DCP375CW Service Manual page 154

Injet dcp/mfc
Hide thumbs Also See for DCP375CW:
Table of Contents

Advertisement

Error Code
Symptom
(Hex)
A5
The white level data is
not compensated
properly (1st time)*.
A6
The white level data is
not compensated
properly (retry)*.
A7
Mismatch between the
type of the CIS mounted
and EEPROM data.
A8
Color parameter
matching error. (Used
for monitoring bugs at
the factory.)
A9-AE
Not used.
AF
The CIS unit does not
travel to the specified
position.
B0-B8
Not used.
B9
Light intensity error of
the LED array.
(Exceeding the upper
limit)
BA-BC
Not used.
BD
Black level data error.
* For MFC only
Probable Cause
CIS defective
White reference film stained
in the scanner cover
Main PCB defective
Scanner cover containing the
improper CIS type mounted
at repair
---
CIS flat cable broken or not
connected properly
CIS motor harness not
connected properly
CIS motor defective
CIS drive unit defective
CIS defective
Main PCB defective
CIS defective
Main PCB defective
CIS defective
Main PCB defective
4-22
Solution
Replace the scanner cover
(scanner unit).
Replace the main PCB.
Check the CIS type mounted
and enter the new CIS type into
the EEPROM with Function
code 59 in the maintenance
mode. (Refer to
Chapter 9,
Section
9.4.17.)
Install the latest firmware.
- Correct the cable connection.
- Replace the scanner cover
(scanner unit).
Correct the harness
connection.
Replace the scanner cover
(scanner unit).
Replace the main PCB.
Replace the scanner cover
(scanner unit).
Replace the main PCB.
Replace the scanner cover
(scanner unit).
Replace the main PCB.
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents