Nightly Shutdown: Turn oven burner valve OFF.
Complete Shutdown: Turn oven burner valve OFF. Turn main gas supply OFF.

CONVECTION OVEN PILOT

Before lighting oven, be sure that range top sections have been lit.
1. Connect range to the main electrical supply line. Open oven door panel and locate square pilot
lighter cutout.
2. Turn red gas valve (located behind the control panel) ON, purging the gas line of all air. Turn gas
valve and power switch OFF. Close oven door.
3. Light oven pilot by depressing the red ignition button (see Fig. 1), and using a taper, ignite the pilot.
Hold ignition button in for 30 seconds, or until pilot remains lit. Turn gas valve back ON.
4. If pilot fails to light, turn main gas valve OFF. Wait 5 minutes and repeat Steps 2 and 3.
5. After pilot is lit, push the power switch ON and turn the temperature dial to the desired setting.
Nightly Shutdown: Turn power switch OFF and the temperature dial to 0 degrees.
Complete Shutdown:
1. Push power switch OFF.
2. Turn red gas valve (located behind the control panel) OFF.
3. Turn main gas supply OFF.
4. Disconnect electrical supply cord.
WARNING: THE RANGE AND ITS PARTS ARE HOT. BE CAREFUL WHEN OPERATING, CLEANING
OR SERVICING THE RANGE.

Pilot Burner Adjustments

All adjustment procedures associated with pilot lighting are to be performed by an authorized Vulcan-
Hart installation or service person.
After adjustments are complete, replace oven control panel(s). Check identification so that each panel
is returned to its respective range. Replace oven baffles and oven bottom(s).
Replace upper manifold panel(s). Position brick in ranges where necessary. Replace top casting(s).
Check identification so that each may be returned to its respective original range as received from the
factory.