Maintenance; I Fuse Replacement; I Memory Backup; I Cleaning - Icom I706MKTMG Instruction Manual

Hf/vhf/uhf all mode transceiver
Table of Contents

Advertisement

I Fuse replacement

If a fuse blows or the transceiver stops functioning, try
to find the source of the problem, and replace the
damaged fuse with a new, rated fuse.
Caution:
Disconnect the DC power cable from the
transceiver when changing a fuse.
The IC-706MKIIG has 2 types of fuses installed for
transceiver protection.
• DC power cable fuses ...................................... 30 A
• Circuitry fuse ............................. F.G.M.B. 125 V 4 A
CIRCUITRY FUSE REPLACEMENT
The 13.8 V DC from the DC power cable is applied to
all units in the IC-706MKIIG, except for the power
amplifier, through the circuitry fuse. This fuse is
installed in the PA unit.

I Memory backup

All of the CPU's memory is backed up by an EEP-
ROM (Electronically-Erasable Programmable Read-
Only Memory). All data you set, such as VFO, mem-
ory, set mode contents, etc. is stored in this EEP-
ROM. There is no internal lithium battery.

I Cleaning

If the transceiver becomes dusty or dirty,
wipe it clean with a dry, soft cloth.

MAINTENANCE

DC POWER CABLE FUSE REPLACEMENT
4 A Fuse
AVOID the use of strong chemical solvents
such as thinner, benzine or alcohol to clean
the transceiver. These may damage the
transceiver's surfaces.
8
30 A fuse
56