If the memory module has not been correctly inserted, it may cause
a fire. Insert the memory module with attention to its direction.
If a memory module is installed and you pull the lever strongly
outwards, the memory module pops up. Doing so may cause a device
failure.
Please observe the safety information in
information" on page
If a defective non-hot-plug component is detected (further information can be
found in chapter
"Starting up and operation" on page 67
"ServerView Suite Local Service Concept - LSC" manual on the
ServerView Suite DVD 2), proceed as follows:
Ê Exit all applications and shut down the server properly (see section
"Switching the server on and off" on page
Ê Pull all power connectors out of the power outlets.
Ê Open the server (see section
Ê Press the Indicate CSS button on the system board (see the technical
manual for the system board D2619-N).
The PRIMERGY Diagnostic LED of the defective CSS component lights up
orange, thereby indicating which CSS component (memory module, fan or
expansion card) on the system board must be replaced (see technical
manual for the system board D2619-N).
RX300 S6
31.
79).
"Opening/closing the housing" on page
Operating manual
Non-hot-plug components
chapter "Important
and the
119).