Service Personnel Initial Settings Table 2.9.2.3 (9/11)
T.F.
Item
No.
27
Media type
28
Transfer roller latch
current
29
V34 TX retry
30
Symbol rate
31
NSF switch
Service Guide OKIFAX 5750/5950
Chapter 2 Installation
Specifications
Set the recording paper quality (thickness).
1) Setting values
M (Medium)/MH (Thicker than medium)/H (Thick) selectable.
Set an imprinting latch current value.
1) Setting values
-2/-1/0/+1/+2 selectable.
Determine whether the V34 communication error is to be
remembered.
1) Setting values
ON: Remembered
OFF: Nor remembered
Set the V.34 modem symbol rate.
1) Setting values
2400/2800/3200/3429 selectable.
Determine whether the NSS/NSF signal is to be sent out.
1) Setting values
ON: Sent
OFF: Not sent
* If data is transmitted with this setting OFF, DCS OKIFAX
5750/5950 transmission is performed (NSC is not sent) even if
the Oki NSF is received.
Relay initiate transmission operation cannot be performed.
* If REMOTE DIAGNOSIS is set to ON although NSF Switch (this
setting) is set to OFF, an NSF is sent and sent immediately if
Oki's original function is ON (confidential, etc.).