16
T2 timer *100ms
Copyright 2000, Oki Data, Division of OKI America, Inc. All rights reserved. See the Oki Data Business Partner Exchange
(BPX) for any updates to this material. (http://bpx.okidata.com)
1) Setting values
10-255 selectable (in 1 second steps)
* Enter a value with ten-keys.
Set the T2 timer. The T2 timer is an EOL (End Of
Line) signal interval timer used for G3 image
reception or an instruction reception
wait timer.
If any signal cannot be detected within the timer-set
time, the fax disconnects the line.
1) Setting values
1-255 selectable (in 100 ms steps)
* Enter a value with ten-keys.
* Actual value = (Set value) x 100 ms
Suppose the set value is 060, then
060 x 100 ms = 6 s