Service Personnel Initial Settings Table 2.9.2.3 (1/11)
l
Table 2.9.2.3 shows the initial setting items and their purpose. (The default setting is different by the individual countries.)
l
Each item can be accessed by entering it on Technical Setup.
l
The detailed procedures of the initial settings items will be explained on the following tables.
The setting data must be transferred to the G3 Option side.
(encluding LLC CHECK, G3/G4 LEARNING, GATEWAY SERVICE, EMAIL MAINTENANCE, ADMIN EMAIL ADDR. and COMMAND T.O.)
T.F.
Item
No.
01
Service bit
02
Monitor control
03
Country code
Service Guide OKIFAX 5750/5950
Chapter 2 Installation
Specifications
Enables the serviceman to make special settings. If this setting is
OFF, some settings and report print function may become unavailable.
1) Setting values
ON: Enables the serviceman to make settings.
OFF: Disables the serviceman to make settings.
Sets up the line monitor.
If this setting is OFF at the time of transmission, the line is monitored
during dialing but the line will not be monitored after a specified time
lapse (about 5 sec).
If this setting is ON, the line will be monitored till the end of
communication.
1) Setting values
ON: Monitored continuously
OFF: Not monitored continuously
* The tone level can be adjusted by setting Monitor Volume.
1) Setting values
Select a country code:
USA/INT/GBR/IRL/NOR/SWE/FIN/DEN/GER/HUN/TCH/POL/SUI/AUT
/BEL/HOL/FRE/POR/ESP/ITA/GRE/AUS/NZL/SIN/HNG/LTA/MEX
* The setting data must be transferred to the G4 board.
* Setup a dial parameter when changing a country code.
* Distinctive ring sets to OFF.
* In case Country code is changed in FRE:
Forcibly, set to 7dB when the attenuator setting
values are set between 0dB to 6dB.