B. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing closer than the
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.)
Failure to comply could cause fi re.
Note: For non-combustible fi replace fi nish material (marble,
stone, etc) specifi cations refer to Section 13.C.
Combustible Mantels (Combustible/Non-Combustible)
10 mm
Thick Wall
Sheathing
360 mm
Figure 13.7 Clearances To Combustible Mantels Or Other
Combustibles Above Appliance
Note: For non-combustible fi replace fi nish material (marble,
stone, etc) specifi cations refer to Section 13.C.
48
300 mm
MAX.
MEASUREMENT
FROM TOP OF
FIREPLACE
MIN.
OPENING
Heat & Glo • XLR-N-AU, XLR-PB-AU • 2198-906 Rev. C • 3/10
Mantel Leg (Combustible/Non-Combustible)
TOP VIEW
80 mm
MINIMUM
180 mm
Figure 13.8 Non-Combustible Mantel Leg or Wall
Projections
(Acceptable on both sides of opening)
Front Side Finishing Detail
37 mm
Figure 13.9 Front Side Finishing Detail
UNLIMITED
30 mm
FRAMING
10 mm BUILDING MATERIAL