READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
- Do not store or use gasoline or other
flammable vapors and liquids in the vi-
cinity of this or any other appliance.
-
What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your build-
ing.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
- Installation and service must be
performed by a qualified installer, service
agency, or the gas supplier.
Printed in U.S.A. Copyright 2005
Heat & Glo, a brand of Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471,
5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165,
6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802,
6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250,
780403, 1418504 or other U.S. and foreign patents pending.
Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06
Owner's Manual

Installation and Operation

WARNING: IMPROPER INSTALLA-
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
1. This appliance may be installed in an af-
termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed
plumber or gas fitter;
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.
Please contact your Heat & Glo dealer with any
questions or concerns. For the number of your nearest
Heat & Glo dealer, please call 1-888-427-3973.
Underwriters
Laboratories Listed
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo 6000TR-OAK

  • Page 1: Installation And Operation

    6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 2: Safety And Warning Information

    DO NOT place furniture or any other combustible Young children should be CAREFULLY SUPERVISED household objects within 36 inches of the fireplace when they are in the same room as the appliance. front. Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 3: Table Of Contents

    Step 12 Before Lighting the Fireplace ........34 Step 13 Lighting the Fireplace ..........35 After the Installation ..............35 Section 4: Maintaining and Servicing Your Fireplace ..35 = Contains updated information. Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 4: Section 1: Approvals And Codes

    Code (in Canada). These models may be installed in a bedroom or bed-sitting room in the U.S.A. and Canada. Heat & Glo Quality Systems registered by SGS ICS Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    (1/2) inch in size, “GAS See Gas Connection section for additional Common- VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- wealth of Massachusetts requirements. STRUCTIONS”. Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 6: Section 2: Getting Started

    Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 7 [1040mm] TOP STANDOFFS TOP VENT COLLARS REAR VENT COLLARS HOOD TRIM DOOR RATING PLATE AND LABELS LINE ACCESS ELECTRICAL ACCESS CONTROLS Figure 1. Diagram of the 6000TR-OAK, 6000TR-OAK-IPI Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 8: Section 3: Installing The Fireplace

    The back of the fireplace may be recessed 21 1/2 inches (546 mm) into combustible construction. For minimum clearances, see the direct vent termination clearance diagrams on pages 24 and 25 in this manual. Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 9: Step 2 Framing The Fireplace

    The center of the hole is one (1) inch (25.4mm) above the center of the horizontal vent pipe. 0” CLEARANCE TO Figure 3. Framing Dimensions 0” CLEARANCE FRAMING MEMBER Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 10 1-1/4 TYP DVP48 8-9/16 1/2 TYP 12-9/16 NOTE: PIPES OVERLAP 1-1/4 INCHES AT EACH JOINT. Figure 4. DVP-Series Direct Vent Component Specifications (5-inch inner pipe / 8-inch outer pipe) Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 11: Step 3 Installing The Vent System

    (For use on IPI units only) FIRESTOP DVP-TRAP DVP-TVHW DVP-TB1 SERIES (Required to have a minimum of 3 feet of vertical in the vent system) Figure 5. Vent System Components and Termination Kits Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 12 2. Break the Flue Restrictor into two pieces. Do this by bending the part back and forth until it breaks (see Figure 8). Figure 6. Straight Up Vertical Venting BREAK HERE Figure 8. Flue Restrictor Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 13 NOTE: This model is tested and approved to use 45° elbows in corner installations. Howev- er, 90° elbows will result in better performance. Figure 11. Corner Installation SETTINGS Figure 10 Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 14 NOTE: If a 90 elbow is first attached to the unit, the maximum horizontal run is 3-feet (914mm). Figure 13. Venting with One 90° Elbow Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 15 15´ MAX. (4.65m) 4' MIN. (1.22m) 20´ MAX. (6.2m) V+H+H = 40' MAX.(12.4m) = 20´ MAX. (6.2m) +H = 40' MAX.(12.4m) Figure 15. Venting with Two 90° Elbows Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 16 8´MAX. (2.48m) 20´MAX. (6.2m) V+H+H = 40 MAX. (12.4 m) H = 8´ MAX. (2.48 m) = 20´ MAX. (6.2 m) ´ Figure 16. Venting with three 90° elbows Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 17 15' MAX. (4.65m) 4' MIN. (1.22m) 20' MAX. (6.2m) H +H = 20' MAX. (6.2m) +H +H = 40' MAX. (12.4m) NOTE: Figure 17. Venting with three 90° elbows Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 18: Installing Vent Components

    SHIELD DISCARD BOTH Vent Termination. PIECES and HEAT SHIELD HEAT DISCARD SHIELD INSULATION HEAT SHIELD HERE Cut the seal cap strap and remove white gasket material. Figure 18 Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 19 1/2 inch airspace between the shield and the combustible surface. See Figure 21. CORRECT INCORRECT COMBUSTIBLE SURFACE DIRECTION HEAT SHIELD 90 ELBOW Figure 21 Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 20 HEAT SHIELD TRIM HEAT SHIELD IF TOO LONG, ADD TO SHIELD IF TOO SHORT EXTERIOR FIRESTOP INTERIOR FIRESTOP Figure 24. Heat Shield, Interior & Exterior Firestops Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 21: Vent Termination

    NOTE: Keep insulation away from the vent pipe at least 1 inch (25mm). NAILS (4 REQUIRED) RAFTER 7-1/4 in. (184mm) Figure 28. Trapezoid Termination Cap CEILING CEILING FIRESTOP Figure 27. Attic Firestop Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 22 Figure 29. Minimum Clearances for Terminations CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 23: Step 4 Positioning, Leveling, And Securing The Fireplace

    • Secure the fireplace to the framing by nailing or screwing. the roof hole (for inside vent installations) or up past the roof line until you reach the appropriate distance above the roof (for outside terminations). Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 24: Step 5 Installing The Optional Heat-Zone-Gas Kit

    3. Determine the location for the air register/fan housing assembly. Reference the Heat-Zone-Gas kit instructions for the re- maining installation steps. INTERMITTENT PILOT IGNITION FLAME SENSOR Figure 33. Gas Control Systems Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 25: Step 7 The Gas Supply Line

    (1/2) psig (3.5 kPa). Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 26: Step 9 Wiring The Fireplace

    REPLACED WITH TYPE 105 C RATED WIRE. JUNCTION BOX BLOWER RECEPTACLE GROUND TEMPERATURE SENSOR SWITCH BLOWER 110-120 VAC SENSOR BLOWER SWITCH “FAN” RECEPTACLE SPEED CONTROL Figure 36. Fan Wiring Diagram Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 27 TION WHEN SERVICING CONTROLS. WIRING ERRORS order to conserve battery life. In the case of a loss of power, CAN CAUSE IMPROPER AND DANGEROUS OPERA- TION. VERIFY PROPER OPERATION AFTER SERVICING. Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 28: Step 10 Finishing

    Note: There are 3 metal tabs holding the non-combustible board in place for shipping. These tabs are to be cut off or bent back before finishing around the fireplace front. Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 29: Step 11 Installing Trim, Logs, And Ember Material

    • Pull the four glass latches out of the groove on the glass fication Council SGCC # 1595 and 1597. Architectural Test- frame. Remove glass door from the unit (see Figure 41). ing, Inc. Reports 02-31919.01 and 02-31917.01.) Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 30: Step 12 Before Lighting The Fireplace

    WING NUT valve has been turned to the OFF position, in which Figure 43. case the air would have to be purged. Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...
  • Page 31: Step 13 Lighting The Fireplace

    DO See Figure 44. The flame sensor (IPI) or thermopile/ NOT use abrasive cleaners. thermocouple (standing pilot) tips should be covered with flame. See Figure 33. Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI • 383-901 Rev. K • 5/06...