12
12

Electrical Information

A. Wiring Requirements
NOTICE: This appliance must be installed by a qualifi ed
electrician in accordance with the relevant national and
local regulations.
• Wire the appliance junction box to 220-240 VAC. This is
required for proper operation of the appliance (IntelliFire
ignition).
WARNING! Risk of Shock or Explosion! DO NOT wire
220/240 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.
NOTICE: The mains supply to the appliance must have
isolation of a minimum 3 mm contact separation in both
poles.
WARNING! Risk of Injury! The gas supply shall be shut
off prior to disconnecting the electrical power and remov-
ing batteries (if installed) before proceeding with any
maintenance to the appliance.
B. IntelliFire Ignition System Wiring
• Wire the appliance junction box to 220-240 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 12.1, IntelliFire Pilot Ignition (IPI) Wiring
Diagram.
TO JUNCTION BOX
Figure 12.1 IntelliFire Pilot Ignition (IPI) Wiring Diagram with Wall Switch or Thermostat
FLAME
SENSE
GRAY MODULE
Heat & Glo • XLR-N-AU, XLR-PB-AU • 2198-906 Rev. C • 3/10
• This appliance is equipped with an IntelliFire control valve
which operates on a 6 volt system.
• For units installed in Australia, the residence's 220/240
wall outlet to which this appliance's power cord is con-
nected, must be wired to an in-line on/off switch. This is
required for servicing and/or resetting the control module
in the event of a control module LOCK-OUT.
• Plug the 6-volt AC power supply into the appliance junction
box to supply power to the unit.
C. Optional Accessories Requirements
• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
Optional Remote Control Receiver Location
The control module and remote control receiver can be
accessed through the air space between the fi rebox front
and the lower-front fi nishing cover panel. The decora-
tive front and glass assembly must be removed to access
these components.
The IPI control module and the remote control receiver
are placed on the fi rebox bottom.
NOTE: 1. Ignition module, valve, pilot, and
wall switch operate on 6 volts. 220/240 VAC
is required at junction box.
IGNITER
RC100
(OPTIONAL REMOTE CONTROL)
THERMOSTAT WIRE
ASSEMBLY / WALL
SWITCH WIRE
43