Gas Valve Replacement; Pilot Assembly Replacement - Heat & Glo XLR-N-AU Owner's Manual

Fireplace
Hide thumbs Also See for XLR-N-AU:
Table of Contents

Advertisement

G. Gas Valve Replacement
Once the valve assembly has been removed, the gas
valve, pilot assembly, orifi ce fl ex tube, and fl ex ball valve
can be replaced.
Figure 16.8
1. Place the valve assembly on a clean, stable surface to
service or replace any components.
2. Disconnect the orange and green wires from the
valve.
3. Removed the Pilot fi tting from the valve assembly
4. Disconnect the orifi ce gas fl ex and gas ball valve fl ex
from the (2) fl are fi ttings.
5. Unscrew (2) screws located under the pressure taps
to remove the gas valve from the valve bracket.
PILOT
PILOT
FITTING
FITTING
O R I F I C E
O R I F I C E
FLEX
FLEX
FLARE FITTING
FLARE FITTING
Figure 16.9
58
VALVE
VALVE
BRACKET
BRACKET
GAS BALL
GAS BALL
GAS
GAS
VALVE
VALVE
VALVE
VALVE
Heat & Glo • XLR-N-AU, XLR-PB-AU • 2198-906 Rev. C • 3/10
H. Pilot Assembly Replacement
Figure 16.10
1. Disconnect the orange and white wires from the con-
trol module
2. Removed the pilot fi tting from the valve assembly
3. Remove two screws that secure pilot assembly to the
pilot bracket
PILOT
PILOT
BRACKET
BRACKET