Model:
XLR-N-CE
XLR-PB-CE
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
This is a room sealed appliance and no other ventilation is
required than what is provided.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fireplace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other flammable
materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fixed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
These instructions are only valid if the following country symbol is
on the appliance. If this symbol is not present on the appliance,
it is necessary to refer to the technical instructions which will
provide the necessary information concerning the modification
of the appliance to the conditions of use for the country.
These instructions are valid for the following countries: GB, IE.
EC-87/09/058
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo XLR-N-CE

  • Page 1 This is a room sealed appliance and no other ventilation is required than what is provided. These instructions are valid for the following countries: GB, IE. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 2: Congratulations

    Consult instructions before installa- tion and use of this appliance. XXXXXXXX Serial: DO NOT REMOVE OR COVER THIS LABEL. XXXX-XXX Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 3: Table Of Contents

    C. Facing Material ....... . . 47 Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 4 D. Contact Information ......65  = Contains updated information. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 5: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645C 12-29-10 Page 1 of 2 Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 6 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645C 12-29-10 Page 2 of 2 Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 7: Listing And Code Approvals

    Columns highlighted in gray = The gas control valve supplied with this product is approved for a maximum inlet pressure of 37 mbar. For pressures over 37 mbar, an in line pressure regulator must be installed upstream from the gas control valve. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 8: User Guide

    (NOT SHOWN) SECTION 14.E. CLEAR SPACE SECTION 2.C. MEDIA OPTIONS SECTION 2.E MEDIA - BLACK, CLEAR, AMBER, COLBALT MEDIA - BK2 - GEMS, MEDIA WH2-GEMS MEDIA-STONES-2 XLR-LOGS Figure 2.1 General Operating Parts Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 9: Clear Space

    This appliance ships standard without a decorative media option. For installation and removal of these decorative media options, refer to installation instructions which ship with the media options. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 10: Control Module Operation

    This appliance has a safety feature that automatically shuts down the fireplace after nine hours of continuous operation with receiving a command from the wall switch or optional remote. Figure 2.5 Location of Module Reset Switch - Martini Front Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 11: Lighting Instructions (Ipi)

    See installation and operating vice agency or the gas supplier. instructions accompanying appliance. For additional information on operating your Hearth & Home Technologies fireplace, please refer to www.fireplaces.com. Final inspection by Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 12: Battery Tray/Battery Installation

    Wall above appliance feels hot to No action necessary. This appliance ships with a non-combustible material attached. Specifica- the touch. tions of the attached non-combustible material are listed in Section 1.E. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 13: Maintenance And Service

    - Light deposits: Use a soft cloth with soap and water - Heavy deposits: Use commercial fireplace glass cleaner (consult with your dealer) • Reinstall door or decorative front. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 14: Maintenance Tasks-Qualified Service Technician

    • Verify unobstructed air circulation. Gas Pressure Information Frequency: Upon initial installation and gas valve re- placement or service. By: Qualified Service Technician Tools needed: Protective gloves, manometer, flashlight, screw driver set. Figure 3.1 IPI Pilot Flame Pattern Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 15: Installer Guide

    (SECTION 8.D) CEILING FIRESTOP ON FLOOR OF ATTIC (SECTION 8.C) FRAMING HEADED OFF IN CEILING JOISTS (SECTION 8.C) FRAMING/HEADER (SECTION 5) WALL SWITCH GAS LINE (SECTION 11) Figure 4.1 Typical System Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 16: Design And Installation Considerations

    Non-corrosive leak check solution 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (150 ºC minimum continuous exposure rating) One 1/4 in. female connection (for optional fan). Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 17: Framing And Clearances

    Actual installation may vary due to individual design preference. 2,54 cm ALCOVE INSTALLATION TOP VENT ONE 90º ELBOW TOP VENT ONE 90° ELBOW See Section D. Centimeters Figure 5.6 Figure 5.1 Appliance Locations Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 18: Constructing The Appliance Chase

    3,8 nominal, such as with formed steel systems, then it may be necessary to adjust the ad- jacent framing dimensions so that the non-combustible board and wallboard joints are centered on the framing. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 19: Clearances

    Rough Rough Clearance Combustible Combustible Behind Sides of Front of Opening Opening Opening Opening to Ceiling Floor Flooring Appliance Appliance Appliance (Vent Pipe) (Height) (Depth) (Width) Centimeters Figure 5.2 Clearances to Combustibles Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 20: Mantel And Wall Projections

    Note: Factory installed non-combustible board may only be replaced with HHT product code SUPERM-60 material and must be fully replaced in its entirety. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 21: Termination Locations

    39.8°-42.5° ............99 42.5°-45.0° ............1 22 45.0°-49.4° ............1 52 49.4°-53.1° ............1 83 53.1°-56.3° ............2 13 56.3°-59.0° ............2 29 59.0°-60.3° ............2 44 *.91 M minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 22 All gravity air intakes within .91 m of a termination cap must be a minimum requirements. of .30 m below the termination cap. Figure 6.3 Minimum Clearances for Termination Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 23: Vent Information And Diagrams

    45º elbows (see Figure 7.1). must be installed. • Horizontal runs of vent do not require vertical rise; horizontal runs may be level. Vertical 21,6 cm Horizontal Figure 7.1 Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 24 30,5 cm 91,4 cm 61,0 cm 1,5 m 91,4 cm 2,1 m 120 cm 4,3 m H Max. =4,3 m V + H Max. = 12,2 m Figure 7.3 Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 25 1,2 m 914 mm 1,8 m 1,2 m 4,6 m H + H Max. =4,6 m V + H + H Max. = 12,2 m INSTALLED HORIZONTALLY Figure 7.4 Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 26 If the vent configuration has a total vertical of 4,6 m - 13,4 m, an exhaust restrictor may be needed. The exhaust restrictor can be located in the ap- pliance manual bag. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 27 + H Max. = 12,2 m * No specific restrictions on this value EXCEPT V + H cannot exceed 12,2 m Note: Use SLP Series components only. Figure 7.8 Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 28 H Max. = 4,3 m Max. = 12,2 m * No specific restrictions on this value EXCEPT V cannot exceed 12,2 m Note: Use SLP Series components only. INSTALLED HORIZONTALLY Figure 7.9 Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 29 Top Vent - Vertical Termination Venting with 4 elbows Min. Max. Min. Max. Min. Note: Use SLP Series 45,7 cm 1,2 m 1,2 m 1,2 m 1,0 m components only. Maximum= 12,2 m Figure 7.10 Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 30: Vent Clearances And Framing

    * Shows center of vent framing hole for top venting. The center of the hole is one 2,54 cm above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 31: Install The Ceiling Firestop

    Figure 8.3 Installing Ceiling Firestop INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 32: Install Attic Insulation Shield

    • Bend all tabs inward 90° around the top of the shield. These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to maintain air space clearance. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 33: Appliance Preparation

    For all venting applications, ensure that the pipe gasket is in place before attaching any pipe section. This gasket is shipped in place around the starting collar. See Figure 9.2. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 34: Securing And Leveling The Appliance

    Figure 9.3 shows the fireplace installed on the floor. However, this fireplace can be elevated off the floor provided that the fireplace is properly supported by framing materials and the ceiling clearances are maintained. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 35: Installing Vent Pipe (Slp Pipe)

    Use care when removing termination cap from slip pipe. If slip section seals are bro- ken during removal of the termination cap, vent may leak. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 36: Assemble Slip Sections

    • Only outer pipes are sealed, sealing the inner flue is not required. • All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 37: Disassemble Vent Sections

    Cut the hole 3 mm larger than the support box outline. • Lower the support box through the hole in the roof until its Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 38: Install Metal Roof Flashing

    • Caulk the perimeter of the flashing where it contacts the roof surface. See Figure 10.12. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Figure 10.14 Assembling the Storm Collar Around the Pipe Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 39: Install Vertical Termination Cap

    • Once the pipe section and the termination cap have been connected, slide the wall thimble up to the interior wall surface and attach with screws provided. See Figure 10.16. Figure 10.16 Wall Thimble Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 40: Install Horizontal Termination Cap

    HEAT SHIELD OR HEAT SHIELD EXTENDED 3,8 CM MIN. HEAT SHIELD OVERLAP WALL SHIELD FIRESTOP SLIP SECTION CAN BE EXTENDED INNER VENT SHEATHING OUTER VENT INTERIOR EXTERIOR Figure 10.17 Venting through the wall Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 41: Gas Information

    Columns highlighted in gray = The gas control valve supplied with this product is approved for a maximum inlet pressure of 37 mbar. For pressures over 37 mbar, an in line pressure regulator must be installed upstream from the gas control valve. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 42: Electrical Information

    WALL SWITCH JUMPER WIRE AUX 1 AUX 2 TO JUNCTION CORD 230 VAC TO OPTIONAL COMPONENTS BATTERY PACK 6V DC THERMOSTAT WIRE ASSEMBLY / WALL SWITCH WIRE Figure 12.1 IntelliFire Plus™ Pilot Ignition (IPI) Wiring Diagram with Wall Switch or Thermostat Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 43: Electrical Service And Repair

    Note: There is an alternative access to the junction cord. This can be accessed by removing the valve assembly. See Figures 11.1 and 11.2. Figure 12.2. Junction Cord Information 240V BLOWER GROUND TERMINAL TO FIREPLACE CHASSIS JUNCTION CORD MODULE AUX 300 CE OPTIONAL COUNTRY OF DESTINATION PLUG Figure 12.3 Blower Circuit Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 44: Finishing

    2. Screw each nailing tab to the adjoining framing material. Ensure that the air space clearance is maintained on the sides of the fireplace. See Figure NAILING TAB 13.2. 1/2 IN. FACTORY-SUPPLIED NON-COMBUSTIBLE BOARD Figure 13.2 Front Side Finishing Detail Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 45 Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 46 30,5 intervals along the joint length. • The wall-board joints should be finished with a Taping Coat, followed by at least two subsequent Finish Coats of joint compound. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 47: Mantel And Wall Projections

    • Facing and/or finishing materials must never overhang finish material. into the glass opening. The non-combustible finish material can be installed up to • Observe all clearances when applying combustible the fireplace opening. materials. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 48 Tonic decorative front. See Figure 13.9. Bottom Joint FACTORY-INSTALLED Figure 13.9 Noncombustible Surface Finishing Material 0 - 10 NON-COMBUSTIBLE cm Thick-Inside Fit Method (Tonic Decorative Front BOARD Only) 0-10 cm 1,9 cm 52 cm APPLIANCE OPENING (HEIGHT) 4,6 cm 0-10 cm DRYWALL OR EQUIVALENT (1,3 cm) Figure 13.8 Inside Fit Method (Tonic Decorative Front Only) Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 49: Decorative Fronts

    113 cm Inside dimension decorative front (height). 32,7 cm TONIC DECORATIVE FRONT (TN-SLR-**) Outside dimension of decorative front (height). 49,5 cm Figure 13.10 Tonic Decorative Front Overlap Fit Only See Section 13.C. MARTINI DECORATIVE FRONT (MT-SLR-**) Figure 13.11 Martini Decorative Front Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 50: Appliance Setup

    4. Put pressure on the glass as you allow the glass assem- bly to drop into the two lower tabs. See Figure 14.1. 5. Tilt top of glass towards fireplace and engage both top spring latches. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 51: Air Shutter Setting

    Install only approved media options. These options include: • MEDIA-AMBER • MEDIA-BLACK • MEDIA-CLEAR • MEDIA-COBALT • MEDIA-BK2 GEMS • MEDIA-WH2 GEMS • MEDIA-GEMS • PORC-BASE • XLR-LOGS • MEDIA-STONES-2 Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 52: Troubleshooting

    Verify module is securely grounded to metal chassis of appliance. d. Module voltage output / Valve/Pilot Verify battery voltage is at least 5.7 volts. Replace batteries if volt- solenoid ohms readings. age is below 5.7. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 53 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fine. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 54: Component Access

    4. Verify the replacement module is installed to the wire BURNER CLIP diagram listed in Section 12. ON/OFF/REMOTE SWITCH GAS VALVE BASE PAN Figure 16.4 Remove Burner Assembly CONTROL BATTERY MODULE DC ADAPTER PACK Figure 16.2 Valve Components Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 55: Access Through The Valve Assembly

    See Figure 16.7. VALVE ASSEMBLY GASKET Figure 16.6 Remove Valve Plate 4. Lift the valve assembly up and out to make necessary service or repair. 5. Replace gasket before reinstalling the valve assem- bly. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 56: Gas Valve Replacement

    5. Unscrew (2) screws located under the pressure taps to remove the gas valve from the valve bracket. PILOT VALVE FITTING BRACKET GAS BALL VALVE VALVE O R I F I C E FLEX FLARE FITTING Figure 16.9 Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 57: Reference Materials

    ACCESS LEFT VIEW FRONT VIEW RIGHT VIEW Location Centimeters Location Centimeters 121,8 109,2 95,9 99,3 33,7 16,8 100,6 15,2 17,4 43,8 119,5 46,4 23,7 65,7 42,5 24,8 Figure 17.1 Appliance Dimensions Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 58: Vent Components Diagrams

    29,5 cm 30,8 cm 356 cm 18,1 cm DRC-RADIUS 14,6 cm Cap Shield COOL-ADDM Cap Shield 30,2 cm 12,7 cm 35,2 cm DVP-BEK2 DVP-HPC Cap Brick Extension Figure 17.2 Vent Components Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 59 SLP48 121,9 1219 SLP6A 5 - 15 51 - 152 DVP-HSM-B SLP-PIPE SLP12A 5 - 30 51 - 305 Extended Heat Shield SLP-FS SLP-WS SLP-HVS Ceiling Firestop Wall Shield Firestop Horizontal Pipe Support Figure 17.3 SLP Series Vent Components Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 60 B. Vent Components Diagrams (continued) SLP-TVHW SLP-CCS-BK SLK-SNKD Vertical Cathedral Ceiling Snorkel Termination Cap Support Box-Black Termination Cap SLP-DCF-BK SLP-WT-BK SL-2DVP Ceiling Firestop Wall Thimble-Black Adapter Black 30,5 cm 17,8 cm 39,4 cm DVP-FBHT SLP90 SL-2DVP DVP-FBHT Figure 17.4 SLP Series Vent Components Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 61 Horizontal Termination Cap Effective Length 33,0 cm 20,6 cm 14,6 to 21,3 cm 14,0 cm 21,3 cm 3° 87° 38,1 cm 26,7 cm 27,6 cm SLP-HRC-SS SLP-HRC-ZC-SS HORIZONTAL TERMINATION CAP Figure 17.5 SLP Series Vent Components Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 62: Service Parts

    2184-007 Burner P & B 2198-007 Base Pan 2198-115 GLA-SLR Glass Door Assembly Junction Cord 2166-374 Thermostat Wire 2118-170 Additional service part numbers appear on following page. 3/13 Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 63 2098-320A 14.12 Power Supply 2166-305 Orifi ce N (#42C) 582-842 Orifi ce B (#55C) 582-855 Orifi ce P (.057C) 582-057 Additional service part numbers appear on following page. Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 64 P2B-XLR-CE Conversion Kit P N2PB-XLR-CE Pilot Orifi ce N 593-528 Pilot Orifi ce B 593-529 Pilot Orifi ce P 593-527 Regulator N NGK-DXF-NP Regulator P & B LPK-DXF-NP Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...
  • Page 65: Contact Information

    5890485, 5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945B Printed in U.S.A. - Copyright 2013 Heat & Glo • XLR-N-CE, XLR-PB-CE • 2198-900 Rev. L • 3/13...

This manual is also suitable for:

Xlr-pb-ce

Table of Contents