14. INSTALLATION STATUS CONFIRMATION

Installation status for the Infrared Transmitter/Receiver unit, Chairman unit, and Delegate units can be
checked from the Central unit. Switch on the power to the Chairman and Delegate units to confirm their
installation status after completing installation and connection.
Note
None of the unit's functions can be used while in installation status confirmation mode, except Priority Speech
initiated from the Chairman unit.
Step 1. Switch on the power to the Central unit while holding
down its Installation Check button .
The Central unit's Battery indicator lights, placing
the unit in installation confirmation mode.
1-1. When a connection check signal is output from the
Central unit, the microphone indicator on the
Chairman or Delegate unit that has received the
signal flashes.
1-2. An acknowledgement signal is transmitted from
each Chairman or Delegate unit.
1-3. A response confirmation signal is output from the
Central unit that has received the acknowledgement
signal, and the microphone indicator on the
Chairman or Delegate unit that has received the
signal changes from flashing to steady ON.
Step 2. Press the Installation Check button for 1 second or
more after confirming the indication.
The Central unit's Battery indicator turns off.
The microphone indicators on the Chairman and
Delegate units also extinguish, and the installation
status confirmation mode is terminated, returning
the system to normal operation mode.
44
Lights
Battery indicator
DATA
BATTERY
POWER
CHAIRMAN UNIT TS-801
POWER
PRIORITY
TALK
Flashes
Extinguished
DATA
BATTERY
POWER
TEST
Lights
TEST