Attaching a YA-642 BNC Plug to the 7C-FB Cable
Step 1. Disassemble the BNC plug as shown in the
figure at right.
Step 2. Strip the jacket 15 mm from the end of the
coaxial cable.
Step 3. Insert the coaxial cable into the open ring.
Step 4. Unravel the braided shield and turn it back, then
peel away the aluminum cladding.
Step 5. Strip the dielectric 5 mm from the cable end.
Step 6. Insert the coaxial cable into the clamping
fixture.
Step 7. Attach the clamping ring to the plug.
Step 8. Insert the clamping fixture assembly into the
plug.
Step 9. Solder the conductor to the plug.
Step 10. Clamp the plug by tightening the clamping
fixture.
36
Clamping
Open ring Clamping
fixture
ring
Braided shield
15 mm
Open ring
Aluminum cladding
Dielectric
Conductor
5 mm
Clamping fixture
Clamping ring
Plug
Clamping fixture
Solder.
(Finished)
Plug