10.5.2. Coaxial cable processing

Coaxial cable
3C-FB and 5C-FB
7C-FB
Note: Purchase both the coaxial cable and the required BNC plugs separately.
Follow the procedure below to attach the BNC connector to the coaxial cable:
Attaching a YA-641 or CC-4901 BNC Plug to the 3C-FB Cable
Step 1. Strip the jacket 10 mm from the end of the
coaxial cable.
Step 2. Slip the tube supplied with the BNC plug over the
jacket.
Step 3. Unravel the braided shield and turn it back, then
peel away the aluminum cladding.
Step 4. Strip the dielectric 4 mm from the cable end.
Step 5. Disassemble the BNC plug as shown in the
figure at right and turn the screw on the plug so
that it loosens partially but remains in position.
Step 6. Insert the coaxial cable into the clamping fixture.
Step 7. Insert the clamping fixture assembly into the
plug.
Step 8. Tighten the screw and then clamp the plug by
tightening the clamping fixture.
32
Applicable BNC plug
YA-641 (1 piece per package), CC-4900 (10 pieces per package),
and CC-4901 (10 pieces per package)
YA-642 (1 piece per package)
Braided shield
10 mm
Aluminum cladding
Dielectric
Conductor
4 mm
Screw
Clamping fixture
Plug
Clamping fixture
Screw
Clamping fixture
Plug
(Finished)
Tube
Screw
Plug