Mode C: Priority Fixed For First-Enabled Unit, And Last-In/First-Out Priority For All Subsequent Units; Mic-Off Function - Toa TS-800 Series Operating Instructions Manual

Ts-800 series infrared conference system
Hide thumbs Also See for TS-800 Series:
Table of Contents

Advertisement

7.2.3. Mode C: priority fixed for first-enabled unit, and last-in/first-out priority for all subsequent units

The first-enabled Chairman or Delegate unit is given fixed speech priority until its Talk key is pressed again.
All subsequent Talk key-enabled units are given last-in/first-out priority, as in Mode B.
• Example showing the number of simultaneous speakers set to [2].
Chairman or Delegate unit
[First unit]
TALK
Press the talk key.
First unit: Speech possible.

7.3. Mic-Off Function

This function automatically turns off the microphone if the user neglects to turn it off following speech
completion.
This function is enabled when the Mic-Off Setting switch on the
TS-800 Central Unit is set to the ON position.
The microphone automatically turns off if a duration of silence
lasts for about 30 seconds.
It is recommended that the Mic-Off switch be set to the OFF
position when not specifically using this function. (The Mic-Off
switch is factory-preset to the OFF position.)
Notes
• When the Mic-Off switch is set to the ON position, the
microphone automatically turns off if there is a silent interval of
about 30 seconds, even though a speech may be in progress.
In conferences, where long pauses during speeches can be
experienced, set the switch to the OFF position.
• The Mic-Off function may not be operated correctly in high-
noise areas.
[Second unit]
TALK
Press the talk key.
First unit:
Speech possible.
Second unit: Speech possible.
[Third unit]
TALK
Press the talk key.
First unit:
Speech possible.
Second unit: Speech cancelled.
Third unit:
Speech possible.
MAX
MIC
1 2 4
[Fourth unit]
TALK
Press the talk key.
First unit:
Speech possible.
Second unit: Speech cancelled.
Third unit:
Speech cancelled.
Fourth unit: Speech possible.
FUNCTION SETTING
DATA–EXTERNAL–PRIORITY
UNIT
PRIORITY
TIME OUT
ON
A B C
OFF
A: FIRST
B: LATEST
C: FIRST: FIXED, NEXT: LATEST
Mic-off setting switch