• UPS monitoring software function list
Function
Required options
Auto shutdown (*1)
UPS monitoring (operating status)
UPS monitoring (data)
Pop-up notification
End when OS is inactive (*3)
Schedule operation
UPS setting change
External command execution
Event log save
Software
Data log save
function
Coordinated shutdown (shutdown
of multiple units)
Output receptacle control
Redundant power supply support
Remote UPS management
Mail send
SNMP management
Telnet connection
SYSLOG support
*1) The UPS automatically stops only when the battery is depleted. (Battery Mode continues until the battery is depleted.)
*2) Only the battery capacity can be monitored.
*3) This function is available only for Windows, not for Linux.
[Explanation of software functions]
1 Auto shutdown
The computer can be shut down automatically when a problem occurs with the power supply.
2 UPS monitoring (operating
The operating status of the UPS can be monitored (in Commercial Power Mode/Battery Mode).
status)
3 UPS monitoring (data)
Monitoring can be performed for input voltage value, connection capacity, battery capacity, etc.
4 Pop-up notification
When a problem such as a power failure occurs, a pop-up window that shows the details of the problem can be displayed.
5 Shutdown when OS is
Shutdown can be performed when the computer is in an inactive state. The operating status is retained at shutdown in inactive
inactive
state, so operation details are not lost.
6 Schedule operation
Schedule settings can be made for UPS stop/start.
7 UPS setting change
UPS settings (beep ON/OFF, etc.) can be changed. (Items that can be set vary according to the UPS.)
8 External command
By executing commands at shutdown, items such as application programs can be launched.
execution
9 Event log save
Information of events that occur on the UPS (power supply problems, setting changes, occurrences of failure, etc.) are saved as
a log.
10 Data log save
Data of input/output voltage value, connection capacity, etc. is periodically saved as a log (the save frequency can be set).
11 Coordinated shutdown
When a problem occurs with the power supply, multiple computers connected to the UPS can coordinate to perform auto
shutdown.
12 Output receptacle control
The UPS output receptacles can be individually set to ON/OFF.
13 Redundant power supply
Two or more UPS can be connected to computers equipped with redundant power supply. Shutdown is not performed when a
support
power supply proble affects only one of the units. Shutdown is performed only when a power supply problem occurs with both
UPS, so the system's operating rate is improved.
14 Remote UPS management The UPS can be managed remotely from a computer on the network.
15 Mail send
When a problem such as a power failure occurs, a notification email describing the problem can be sent to the system
administrator.
16 SNMP management
UPS management information can be sent to the SNMP manager.
17 Telnet connection
Settings such as shutdown parameters can be made via the Telnet connection.
18 SYSLOG support
UPS management information can be recorded in SYSLOG.
General applications
Software title
(Simple functions, standalone)
UPS service
OS standard
driver
UPS service
BUC26
● (*1)
▲ (*2)
75
150
BN
R/BN
● Supported
▲ Limited
Network
management
applications
(Advanced functions,
(Advanced functions,
network support)
Simple
Shutdown
PowerAct Pro 4.x
Software
300
R/BN
R
Unsupported
SNMP management
applications
network support)
SNMP/Web
card
SNMP/Web
card SC20G
7
44