Building Alarm
(See Figure 4-11 for Detail)
REPO Terminals
(See Figure 4-16 for Detail)
Pull chain Terminals
Parallel CAN Input (RJ45)
Parallel CAN Output (RJ45)
Open the door
4-10
7
8
9
10
11
12
13
14

Table 4-1. Building Alarm Connections

Mini-Slot Communication Bays
Interface Terminals
9E 80-120 kVA

Figure 4-10. Interface Terminal Detail (Terminal Cover Removed)

4-11
Building Alarm 1
Building Alarm 2
15
16
17
18
19
20

Figure 4-11. Building Alarm Terminal Block Connector Assignments

Building Alarm Terminal
Name
1
Building Alarm 1 +
2
Building Alarm 1 –
3
Building Alarm 2 +
4
Building Alarm 2 –
5
Building Alarm 3 +
6
Building Alarm 3 –
Mini-Slot
Mini-Slot
Communication Bay 1
Communication Bay 1
Mini-Slot
Communication Bay 1
Mini-Slot
Communication Bay 2
Mini-Slot
Mini-Slot
Communication Bay 2
Communication Bay 2
21
22
23
A0
Description
Input: Programmable UPS alarm, activated by a remote dry contact closure.
Input: Programmable UPS alarm, activated by a remote dry contact closure.
Input: Programmable UPS alarm, activated by a remote dry contact closure.
Eaton 9E UPS (80-200 kVA, 380/400/415V) Installation and Operation Manual
UPS System Installation
Building Alarm
Building Alarm
(See Figure 4-11 for Detail)
See figure 4-12 for detail
REPO Terminals
REPO Terminals
(See Figure 4-16 for Detail)
See figure 4-12 for detail
Pull chain Terminals
Pull Chain Terminals
See figure 4-12 for detail
Parallel CAN Input (RJ45)
Parallel CAN Input (RJ45)
Parallel CAN Output (RJ45)
Parallel CAN Input (RJ45)
9E 160-200 kVA
4-11
Building Alarm 3
EATON CORPORATION
METRIC
THIRD
PROJECTION
DIMENSIONS ARE IN MILLIMETERS AFTER PLATING, DIMENSIONS AND TOLERANCES IN ACCORDANCE WITH ASME Y14.5M-1994. SEE NOTES FOR TOLERANCES.
DESCRIPTION:
ORIGINATED:
ECO:
NAME:
REVISION:
MODIFIED:
4-10-4-11
CHECKED:
DOCUMENT TYPE:
STATE:
SAFETY:
PRO-E DRAWING
APPROVED:
EATON CORPORATION - CONFIDENTIAL AND PROPRIETARY
NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION
THIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE PROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUB
BY EATON AT ANY TIME. BY TAKING POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY MANNER ADVERSE TO THE INTERE
AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIO
NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT.
2
4-9